Journal Home Online First Current Issue Archive For Authors Journal Information 中文版

Engineering >> 2021, Volume 7, Issue 3 doi: 10.1016/j.eng.2020.02.017

Population-Based and Personalized Design of Total Knee Replacement Prosthesis for Additive Manufacturing Based on Chinese Anthropometric Data

a Department of Orthopaedics and Traumatology, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong 999077, China
b Center for Translational Medicine Research and Development, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
c Department of Orthopaedics and Traumatology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008, China
d Institute for Biomechanics, Berufsgenossenschaftliche Unfallklinik Murnau, Murnau am Staffelsee 82418, Germany
e Institute for Biomechanic, Paracelsus Medical University Salzburg, Salzburg 5020, Austria

Received: 2019-07-30 Revised: 2019-12-18 Accepted: 2020-02-21 Available online: 2020-09-05

Next Previous

Abstract

At present, most total knee replacement (TKR) prostheses on the market are designed according to the sizes of Caucasians. However, extensive studies have indicated that human anatomies differ among different ethnicities. A number of reports have indicated that Chinese TKR patients do not match with available prostheses. In this study, computed tomography (CT) images of 52 knees of Chinese men and women were used for anthropometric measurements. Index and geometric measurements were defined and used for correlation analysis. Key parameters from the measurement results were identified. Detailed geometries of knees were measured as coordinates. A deformable three-dimensional (3D) knee model based on anatomical coordinates correlating with the identified key parameters was generated. A prosthesis was then designed according to the analyzed results. Surface matching analysis, bone resection analysis, and cadaveric trials were conducted and compared with commercial products to validate the proposed design. The femoral component designed by this study resulted in the highest accuracy (root mean square point-to-surface (RMS PS), (1.08 ± 0.20) mm) and lowest amount of resected bone volume (27 412 mm3) in comparison with two commercial knee prostheses. This study suggests a new approach for population-based patient-specific femoral prosthesis design. With a single, easily acquired dimension—namely, epicondyle width (ECW)—as input, a patient-specific femoral prosthesis can be designed according to the analyzed measured data and manufactured by additive manufacturing (AM) methods. Meanwhile, the reconstructed femoral condylar surface was compared with the femoral condylar surface in the original CT scanning data. The average RMS PS distance of the reconstructed femoral condylar surface among all data was (1.10 ± 0.18) mm, which is comparable to other statistical shape modeling methods using multiple radiographs as input data. There is a need to develop an anthropometric-based knee prosthesis for the Chinese population. Based on the anthropometry of the Chinese population, our new design fits Chinese patients better and reserves more bone volume compared with current commercial prostheses, which is an essential step toward AM for personalized knee prostheses.

SupplementaryMaterials

Figures

Fig. 1

Fig. 2

Fig. 3

Fig. 4

Fig. 5

Fig. 6

Fig. 7

Fig. 8

References

[ 1 ] Yue B, Varadarajan KM, Ai ST, Tang TT, Rubash HE, Li GA. Differences of knee anthropometry between Chinese and white men and women. J Arthroplasty 2011;26(1):124–30. link1

[ 2 ] Ho WP, Cheng CK, Liau JJ. Morphometrical measurements of resected surface of femurs in Chinese knees: correlation to the sizing of current femoral implants. Knee 2006;13(1):12–4. link1

[ 3 ] Uehara K, Kadoya Y, Kabayashi A, Ohashi H, Yamana Y. Anthropometry of the proximal tibia to design a total knee prosthesis for the Japanese population. J Arthroplasty 2002;17(8):1028–32. link1

[ 4 ] Lombardi AV Jr, Mallory TH, Waterman RA, Eberle RW. Intercondylar distal femoral fracture. An unreported complication of posterior-stabilized total knee arthroplasty. J Arthroplasty 1995;10:643–50. link1

[ 5 ] Liu Z, Yuan G, Zhang W, Shen Y, Deng L. Anthropometry of the proximal tibia of patients with knee arthritis in Shanghai. J Arthroplasty 2013;28(5):778–83. link1

[ 6 ] Editorial Board of Special Issue on Additive Manufacturing. Introduction to the special issue on additive manufacturing. Engineering 2017;3(5):576. link1

[ 7 ] Wang K, Ho CC, Zhang C, Wang B. A review on the 3D printing of functional structures for medical phantoms and regenerated tissue and organ applications. Engineering 2017;3(5):653–62. link1

[ 8 ] Ling K, Huang G, Liu J, Zhang X, Ma Y, Lu T, et al. Bioprinting-based highthroughput fabrication of three-dimensional MCF-7 human breast cancer cellular spheroids. Engineering 2015;1(2):269–74. link1

[ 9 ] An J, Teoh JEM, Suntornnond R, Chua CK. Design and 3D printing of scaffolds and tissues. Engineering 2015;1(2):261–8. link1

[10] Lu B, Li D, Tian X. Development trends in additive manufacturing and 3D printing. Engineering 2015;1(1):85–9. link1

[11] Lipperts M, van Laarhoven S, Senden R, Heyligers I, Grimm B. Clinical validation of a body-fixed 3D accelerometer and algorithm for activity monitoring in orthopaedic patients. J Orthop Translat 2017;11:19–29. link1

[12] Li L, Long J, Cao H, Tang T, Xi X, Qin L, et al. Quantitative determination of residual 1,4-dioxane in three-dimensional printed bone scaffold. J Orthop Translat 2018;13:58–67. link1

[13] Bosma SE, Wong KC, Paul L, Gerbers JG, Jutte PC. A cadaveric comparative study on the surgical accuracy of freehand, computer navigation, and patientspecific instruments in joint-preserving bone tumor resections. Sarcoma 2018;2018:4065846. link1

[14] Mok SW, Nizak R, Fu SC, Ho KWK, Qin L, Saris DBF, et al. From the printer: potential of three-dimensional printing for orthopaedic applications. J Orthop Translat 2016;6:42–9. link1

[15] Fang C, Cai H, Kuong E, Chui E, Siu YC, Ji T, et al. Surgical applications of threedimensional printing in the pelvis and acetabulum: from models and tools to implants. Unfallchirurg 2019;122(4):278–85. link1

[16] Eckhoff DG, Bach JM, Spitzer VM, Reinig KD, Bagur MM, Baldini TH, et al. Three-dimensional mechanics, kinematics, and morphology of the knee viewed in virtual reality. J Bone Joint Surg Am 2005;87(S2):71–80. link1

[17] Eckhoff D, Hogan C, Dimatteo L, Robinson M, Bach J. Difference between the epicondylar and cylindrical axis of the knee. Clin Orthop Relat Res 2007;461:238–44. link1

[18] Berger RA, Rubash HE, Seel MJ, Thompson WH, Crossett LS. Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res 1993;286:40–7. link1

[19] Shi D. Biomechanical study on the application of newly defined posterior condylar axis in the kinematical alignment of varus knees [dissertation]. Hong Kong: The Chinese University of Hong Kong; 2015. link1

[20] Netter FH. Atlas of human anatomy. 6th ed. Philadelphia: Elsevier Saunders; 2014. link1

[21] Shao X. The manual of anthropometry. Shanghai: Shanghai Lexicographical Publishing House; 1985. link1

[22] Howell SM, Roth JD, Hull ML. Kinematic alignment in total knee arthroplasty definition, history, principle, surgical technique, and results of an alignment option for TKA. Arthropaedia 2014;1:44–53. link1

[23] Leardini A, Cappozzo A, Catani F, Toksvig-Larsen S, Petitto A, Sforza V, et al. Validation of a functional method for the estimation of hip joint centre location. J Biomech 1999;32(1):99–103. link1

[24] Inman VT. The joints of the ankle. Baltimore: Williams & Wilkins; 1976. link1

[25] Schneider A, Hommel G, Blettner M. Linear regression analysis—part 14 of a series on evaluation of scientific publications. Dtsch Arztebl Int 2010;107 (44):776–82. link1

[26] Zhu Z, Li G. Construction of 3D human distal femoral surface models using a 3D statistical deformable model. J Biomech 2011;44(13):2362–8. link1

[27] Zheng G, Schumann S. A system for 3-D reconstruction of a patient-specific surface model from calibrated X-ray images. Stud Health Technol Inform 2009;142:453–8. link1

[28] Zheng G, Schumann S. 3D reconstruction of a patient-specific surface model of the proximal femur from calibrated X-ray radiographs: a validation study. Med Phys 2009;36(4):1155–66. link1

[29] Tang TSY, Ellis RE. 2D/3D deformable registration using a hybrid atlas. In: Duncan JS, Gerig G, editors. Lecture notes in computer science. Proceedings of 8th International Conference on Medical Image Computing and ComputerAssisted Intervention; 2005 Oct 26–29; Palm Springs, CA, USA. Berlin: Springer-Verlag; 2005. p. 223–30. link1

[30] Lamecker H, Seebass M, Hege HC, Deuflhard PA. In: Image processing. Proceedings of the Medical Imaging 2004 Conference; 2004 Feb 17–19; San Diego, CA, USA. Bellingham: Spie-Int Soc Optical Engineering; 2004. p. 1341–51. link1

[31] Sadowsky O, Chintalapani G, Taylor RH. Deformable 2D-3D registration of the pelvis with a limited field of view, using shape statistics. In: Ayache, N, Ourdelin S, Maeder A, editors. Lecture notes in computer science. Proceedings of 10th International Conference on Medical Image Computing and ComputerAssisted Intervention; 2007 Oct 29–Nov 2; Brisbane, QLD, Australia. Berlin: Springer-Verlag; 2007. p. 519–26.

[32] Laporte S, Skalli W, de Guise JA, Lavaste F, Mitton D. A biplanar reconstruction method based on 2D and 3D contours: application to the distal femur. Comput Methods Biomech Biomed Eng 2003;6(1):1–6. link1

[33] Vignesh U, Mehrotra D, Howlader D, Singh PK, Gupta S. Patient specific threedimensional implant for reconstruction of complex mandibular defect. J Craniofac Surg 2019;30(4):E308–11. link1

[34] Tarsitano A, Badiali G, Pizzigallo A, Marchetti C. Orbital reconstruction: patient-specific orbital floor reconstruction using a mirroring technique and a customized titanium mesh. J Craniofac Surg 2016;27(7):1822–5. link1

[35] Du H, Tian X, Li T, Yang J, Li K, Pei G, et al. Use of patient-specific templates in hip resurfacing arthroplasty: experience from sixteen cases. Int Orthop 2013;37(5):777–82. link1

[36] Hitt K, Shurman JR, Greene K, McCarthy J, Moskal J, Hoeman T, et al. Anthropometric measurements of the human knee: correlation to the sizing of current knee arthroplasty systems. J Bone Joint Surg Am 2003;85(S4):115–22. link1

[37] Westrich GH, Agulnick MA, Laskin RS, Haas SB, Sculco TP. Current analysis of tibial coverage in total knee arthroplasty. Knee 1997;4(2):87–91. link1

[38] Hoaglund FT, Low WD. Anatomy of the femoral neck and head with comparative data from Caucasians and Hong Kong Chinese. Clin Orthop Relat Res 1980;152:10–6. link1

[39] Luke P, Allison R, Joseph L, Timothy W, Mark G, Geoffrey W. Reduction in bone volume resection with a newer posterior stabilized total knee arthroplasty design. HSS J 2013;9(2):157–60. link1

Related Research