期刊首页 优先出版 当期阅读 过刊浏览 作者中心 关于期刊 English

《机械工程前沿(英文)》 >> 2013年 第8卷 第2期 doi: 10.1007/s11465-013-0260-z

Dependence of error sensitivity of frequency on bias voltage in force-balanced micro accelerometer

1. Department of Mechanical and Electrical Engineering, Chengdu Technological University, Chengdu 611730, China

2. School of Mechatronics Engineering, University of Electronic Technology and Science of China, Chengdu 611731, China

发布日期: 2013-06-05

下一篇 上一篇

摘要

To predict more precisely the frequency of force-balanced micro accelerometer with different bias voltages, the effects of bias voltages on error sensitivity of frequency is studied. The resonance frequency of accelerometer under closed loop control is derived according to its operation principle, and its error sensitivity is derived and analyzed under over etching structure according to the characteristics of Deep Reaction Ion Etching (DRIE). Based on the theoretical results, micro accelerometer is fabricated and tested to study the influences of AC bias voltage and DC bias voltage on sensitivity, respectively. Experimental results indicate that the relative errors between test data and theory data are less than 7%, and the fluctuating value of error sensitivity under the range of voltage adjustment is less than 0.01 μm . It is concluded that the error sensitivity with designed parameters of structure, circuit and process error can be used to predict the frequency of accelerometer with no need to consider the influence of bias voltage.

相关研究