期刊首页 优先出版 当期阅读 过刊浏览 作者中心 关于期刊 English

《结构与土木工程前沿(英文)》 >> 2013年 第7卷 第2期 doi: 10.1007/s11709-013-0203-0

Experimental study on the compressive performance of new sandwich masonry walls

Department of Building Engineering, Tongji University, Shanghai 200092, China

发布日期: 2013-06-05

下一篇 上一篇

摘要

Sandwich masonry wall, namely, multi-leaf masonry wall, is widely applied as energy-saving wall since the interlayer between the two outer leaves can act as insulation layer. New types of sandwich walls keep appearing in research and application, and due to their unique connection patterns, experimental studies should be performed to investigate the mechanical behavior, especially the compressive performance. 3 new types of sandwich masonry wall were investigated in this paper, and 3 different technical measures were considered to guarantee the cooperation between the two leaves of the walls. Based on the compression tests of 13 specimens, except for some damage patterns similar with the conventional masonry walls, several new failure patterns are found due to unique connection construction details. Comparisons were made between the tested compression capacity and the theoretical one which was calculated according to the Chinese Code for Design of Masonry Structures. The results indicate that the contributions of the 3 technical measures are different. The modification coefficient ( ) was suggested to evaluate the contribution of the technical measures on the compression capacity, and then a formula was proposed to evaluate the design compression capacity of the new sandwich masonry walls.

相关研究