期刊首页 优先出版 当期阅读 过刊浏览 作者中心 关于期刊 English

《结构与土木工程前沿(英文)》 >> 2021年 第15卷 第1期 doi: 10.1007/s11709-020-0581-z

Distributed fiber optic monitoring of a CFA pile with a central reinforcement bar bundle

. Centre for Smart Infrastructure and Construction, Department of Engineering, University of Cambridge, Cambridge CB2 1TN, UK.. Department of Engineering, University of Cambridge, Cambridge CB2 1TN, UK

录用日期: 2021-03-02 发布日期: 2021-03-02

下一篇 上一篇

摘要

In this paper, we present an application of distributed fiber optic sensor (DFOS) technology to measure the strain of a continuous flight auger (CFA) test pile with a central reinforcement bar bundle, during a static load test carried out in London. Being distributed in nature, DFOS gives much more information about the pile performance as compared to traditional point sensors, such as identifying cross-sectional irregularities or other anomalies. The strain profiles recorded along the depth of the piles from the DFOS were used to calculate pile deformation (contraction), shaft friction, and tip resistance under various loads. Based on this pile load test, a finite element (FE) analysis was performed using a one-dimensional nonlinear load-transfer model. Calibrated by the shaft friction and tip resistance derived from the monitored data, the FE model was able to simulate the pile and soil performance during the load testing with good accuracy. The effect of the reinforcement cage and central reinforcement bar bundle were investigated, and it was found that the addition of a reinforcement cage would reduce the pile settlement by up to 20%.

相关研究