资源类型

期刊论文 731

会议视频 41

会议专题 1

年份

2024 1

2023 57

2022 84

2021 57

2020 51

2019 46

2018 50

2017 49

2016 41

2015 65

2014 28

2013 41

2012 19

2011 25

2010 27

2009 26

2008 19

2007 23

2006 8

2005 9

展开 ︾

关键词

能源 16

制造强国 8

汽车强国 5

电力系统 5

信息技术 4

制造业 4

智能制造 4

主动控制 3

海上风电 3

2021全球十大工程成就 2

2022全球工程前沿 2

2023全球十大工程成就 2

Z箍缩 2

中长期 2

主动免疫 2

主动防御 2

制造大国 2

功率谱密度 2

发展趋势 2

展开 ︾

检索范围:

排序: 展示方式:

Power quality improvement using fuzzy logic controller for five-level shunt active power filter under

Amar BENAISSA,Boualaga RABHI,Ammar MOUSSI

《能源前沿(英文)》 2014年 第8卷 第2期   页码 212-220 doi: 10.1007/s11708-013-0284-4

摘要: In this paper, a five-level inverter is used as a shunt active power filter (APF), taking advantages of the multilevel inverter such as low harmonic distortion and reduced switching losses. It is used to compensate reactive power and eliminate harmonics drawn from a thyristor rectifier feeding an inductive load (RL) under distorted voltage conditions. The APF control strategy is based on the use of self-tuning filters (STF) for reference current generation and a fuzzy logic current controller. The use of STF instead of classical extraction filters allows extracting directly the voltage and current fundamental components in the - axis without phase locked loop (PLL). The MATLAB fuzzy logic toolbox is used for implementing the fuzzy logic control algorithm. The obtained results show that the proposed shunt APF controller has produced a sinusoidal supply current with low harmonic distortion and in phase with the line voltage.

关键词: active power filter (APF)     harmonics isolator     distorted voltage conditions     self-tuning filters (STF)     fuzzy logic control    

Rapid transaction to load variations of active filter supplied by PV system

M. BENADJA,S. SAAD,A. BELHAMRA

《能源前沿(英文)》 2014年 第8卷 第3期   页码 335-344 doi: 10.1007/s11708-014-0325-7

摘要: This paper deals with the analysis and control of a photovoltaic (PV) system connected to the main supply through a Boost converter and shunt active filter supplied by a PV system providing continuous supply of nonlinear load in variation. A robust control of a PV system connected to the grid while feeding a variable nonlinear load is developed and highlighted. This development is based on the control of the Boost converter to extract the maximum power from the PV system using the Perturb and Observe (P and O) algorithm in the presence of temperature and illumination. The proposed modeling and control strategy provide power to the variable nonlinear load and facilitates the transfer of power from solar panel to the grid while improving the quality of energy (harmonic currents compensation, power factor compensation and dc bus voltage regulation). Validation of the developed model and control strategy is conducted using power system simulator Sim-Power System Blockset Matlab/Simulink. To demonstrate the effectiveness of the shunt active filter to load changes, the method of instantaneous power ( theory) is used to identify harmonic currents. The obtained results show an accurate extraction of harmonic currents and perfect compensation of both reactive power and harmonic currents with a lower THD and in accordance with the IEEE-519 standard.

关键词: solar panels     maximum power point tracking (MPPT)     DC/DC converter (Boost)     shunt active filter     instantaneous power control     power quality     harmonics     imbalances     reactive energy    

Robust switched fractional controller for performance improvement of single phase active power filter

H. AFGHOUL,F. KRIM,D. CHIKOUCHE,A. BEDDAR

《能源前沿(英文)》 2016年 第10卷 第2期   页码 203-212 doi: 10.1007/s11708-015-0381-7

摘要: A novel controller is proposed to regulate the DC-link voltage of a single phase active power filter (SPAPF). The proposed switched fractional controller (SFC) consists of a conventional PI controller, a fractional order PI (FO-PI) controller and a decision maker that switches between them. Commonly, the conventional PI controller is used in regulation loops due to its advantages in steady-state but it is limited in transient state. On the other hand, the FO-PI controller overcomes these drawbacks but it causes dramatic degradation in control performances in steady-state because of the fractional calculus theory and the approximation method used to implement this kind of controller. Thus, the purpose of this paper is to switch to the PI controller in steady-state to obtain the best power quality and to switch to the FO-PI controller when external disturbances are detected to guarantee a fast transient state. To investigate the efficiency and accuracy of the SFC considering all robustness tests, an experimental setup has been established. The results of the SFC fulfill the requirements, confirm its high performances in steady and transient states and demonstrate its feasibility and effectiveness. The experiment results have satisfied the limit specified by the IEEE harmonic standard 519.

关键词: conventional PI controller     fractional calculus (FC)     total harmonic distortion (THD)     Oustaloup continuous approximation (OCA)     single phase active power filter (SPAPF)    

A simple digital control algorithm for three phase shunt active filter: simulation and experimentation

Subbaraman SRINATH, Chandan KUMAR, M. P. SELVAN

《能源前沿(英文)》 2014年 第8卷 第1期   页码 119-128 doi: 10.1007/s11708-013-0288-0

摘要: A novel and simple control algorithm using digital signal processor (DSP) has been proposed and realized for a three phase shunt active filter (SAF). The simulation and prototype construction of SAF is conducted to compensate the reactive power and harmonics in a distribution system. The major feature of the proposed algorithm is that it does not require unit vector templates and any transformations for the reference current generation of SAF. This reduces the computational complexity and makes the control flexible and faster. The simulation is conducted in MATLAB/SIMULINK while DSP TMS320LF2407 is employed in the digital implementation of hysteresis current control (HCC) for experimentation. The hardware results correlate with the simulation results in reducing the total harmonic distortion (THD) of the source current and achieving unity power factor.

关键词: shunt active filter (SAF)     power quality     voltage source inverter (VSI)     digital signal processor (DSP)     total harmonic distortion (THD)     power factor improvement    

基于迭代算法的有源电力滤波器谐波电流实时检测新方法

李自成,孙玉坤

《中国工程科学》 2006年 第8卷 第1期   页码 46-50

摘要:

目前,已经提出了多种有源电力滤波器谐波及无功电流检测方法,尽管这些方法各有特点,但都存在着难以克服的问题,如计算量大,实时性差,检测精度不高等。文章在负载电流分析的基础上,提出了一种基于迭代算法的有源电力滤波器谐波电流实时检测方法,该方法具有计算量非常小,实时性好,检测精度高等特点。理论分析与仿真研究证实了该方法的正确性。

关键词: 有源电力滤波器     谐波电流     有功电流     无功电流    

Unified power quality conditioner based on a three-level NPC inverter using fuzzy control techniques

Salim CHENNAI,M-T BENCHOUIA

《能源前沿(英文)》 2014年 第8卷 第2期   页码 221-239 doi: 10.1007/s11708-014-0317-7

摘要: This paper presents a novel and efficient control scheme for unified power quality conditioner (UPQC) based on three-level neutral point clamped (NPC) inverter using fuzzy logic techniques. The proposed UPQC is capable of mitigating source current harmonics and compensate all voltage disturbances such as voltage sags, swells, unbalances and harmonics. It is designed by the integration of series and shunt active filters (AFs) sharing a common DC bus capacitor. The DC voltage is maintained constant using proportional integral voltage controller. The synchronous reference frame (SRF) theory is used to get the reference signals for shunt active power filters (APFs) and the power reactive theory (p-q theory) for series APFs. The shunt and series APF reference signals derived from the control algorithm and sensed signals are injected in two controllers to generate switching signals. To improve the UPQC capability, fuzzy logic techniques are introduced to control the series APF. The performances of the proposed UPQC system are evaluated in terms of power factor correction, mitigation of voltage or current harmonics and all other voltage disturbances compensation using Matlab-Simulink software and SimPowerSystem toolbox. The simulation results illustrate the performance of the proposed UPQC at the common connection point of the nonlinear load to improve the power energy quality.

关键词: three-level neutral point clamped (NPC) inverter     unified power quality conditioner (UPQC)     current harmonics mitigation     fuzzy logic controller     voltage disturbance compensation     shunt active filter     series active filter     power quality energy improvement    

电流型有源电力滤波器的神经网络滞环控制

王萍,张珂,许会军

《中国工程科学》 2007年 第9卷 第1期   页码 40-43

摘要:

神经网络滞环控制就是将神经网络和滞环比较器这两种方法相结合的一种控制方法。滞环控制是控 制方法中较为简单的一种,它不需要系统太多的参数,实时性较好,但用滞环控制方法时系统开关频率不固定, 这不仅影响电子开关的使用寿命,而且降低了系统的稳定性。将二者结合的控制方法不仅可实现神经网络对快 速变量的控制,而且可以提高滞环控制的性能。通过训练神经网络能够完成滞环比较器的功能,并可取代滞环 比较器。给出了计算机仿真结果,神经网络通过DSP实现。

关键词: 有源滤波     神经网络     滞环比较器    

多模块并联有源电力滤波器系统及其基于分相控制和实时总线通讯的新型容错控制策略 None

Qun-wei XU, Jin-xiang ZHAN, Long XIAO, Guo-zhu CHEN

《信息与电子工程前沿(英文)》 2018年 第19卷 第9期   页码 1166-1179 doi: 10.1631/FITEE.1601296

摘要: 首先,提出一种适用于大容量补偿的多模块并联有源电力滤波器系统。该系统中每个模块具备相同的电路拓扑、功能及控制器设计,有助于模块间协同控制的实现。模块指令信号由总指令信号与相应的分配系数相乘所得。其次,提出一种基于a-b-c坐标系下分相控制和实时总线通讯的新型容错控制策略。当某一相发生故障时,所提策略仅隔离故障桥臂而非停运整个模块,同时重新计算分配系数,将故障相的补偿容量转移到其他正常模块的相同相,使故障模块得以持续运行以及剩余可用功率器件优化利用。故障后电路的稳态分析证明系统具备高稳定性及控制可靠性,保证其工程应用价值。最后,搭建了实验样机,实验结果验证了所提多模块系统及其容错控制策略的可行性和有效性。

关键词: 并联有源电力滤波器;容错拓扑;分相控制;总线通讯    

UPFC setting to avoid active power flow loop considering wind power uncertainty

Shenghu LI, Ting WANG

《能源前沿(英文)》 2023年 第17卷 第1期   页码 165-175 doi: 10.1007/s11708-020-0686-z

摘要: The active power loop flow (APLF) may be caused by impropriate network configuration, impropriate parameter settings, and/or stochastic bus powers. The power flow controllers, e.g., the unified power flow controller (UPFC), may be the reason and the solution to the loop flows. In this paper, the critical existence condition of the APLF is newly integrated into the simultaneous power flow model for the system and UPFC. Compared with the existing method of alternatively solving the simultaneous power flow and sensitivity-based approaching to the critical existing condition, the integrated power flow needs less iterations and calculation time. Besides, with wind power fluctuation, the interval power flow (IPF) is introduced into the integrated power flow, and solved with the affine Krawcyzk iteration to make sure that the range of active power setting of the UPFC not yielding the APLF. Compared with Monte Carlo simulation, the IPF has the similar accuracy but less time.

关键词: active power loop flow (APLF)     unified power flow controller (UPFC)     wind power uncertainty     interval power flow (IPF)    

Performance of PI controller for control of active and reactive power in DFIG operating in a grid-connected

Azzouz TAMAARAT,Abdelhamid BENAKCHA

《能源前沿(英文)》 2014年 第8卷 第3期   页码 371-378 doi: 10.1007/s11708-014-0318-6

摘要: Due to several factors, wind energy becomes an essential type of electricity generation. The share of this type of energy in the network is becoming increasingly important. The objective of this work is to present the modeling and control strategy of a grid connected wind power generation scheme using a doubly fed induction generator (DFIG) driven by the rotor. This paper is to present the complete modeling and simulation of a wind turbine driven DFIG in the second mode of operating (the wind turbine pitch control is deactivated). It will introduce the vector control, which makes it possible to control independently the active and reactive power exchanged between the stator of the generator and the grid, based on vector control concept (with stator flux or voltage orientation) with classical PI controllers. Various simulation tests are conducted to observe the system behavior and evaluate the performance of the control for some optimization criteria (energy efficiency and the robustness of the control). It is also interesting to play on the quality of electric power by controlling the reactive power exchanged with the grid, which will facilitate making a local correction of power factor.

关键词: wind power     doubly fed induction generator (DFIG)     vector control     active power     reactive power     maximum power point tracking (MPPT)    

H control in the frequency domain for a semi-active floor isolation system

Yundong SHI, Tracy C BECKER, Masahiro KURATA, Masayoshi NAKASHIMA

《结构与土木工程前沿(英文)》 2013年 第7卷 第3期   页码 264-275 doi: 10.1007/s11709-013-0214-x

摘要: A floor isolation system installed in a single floor or room in a fixed base structure is designed to protect equipment. With this configuration, the input motions to the floor isolation from the ground motions are filtered by the structure, leaving the majority of the frequency content of the input motion lower than the predominant frequency of the structure. The floor isolation system should minimize the acceleration to protect equipment; however, displacement must also be limited to save floor space, especially with long period motion. Semi-active control with an control was adopted for the floor isolation system and a new input shaping filter was developed to account for the input motion characteristics and enhance the effectiveness of the control. A series of shake table tests for a semi-active floor isolation system using rolling pendulum isolators and a magnetic-rheological damper were performed to validate the control. Passive control using an oil damper was also tested for comparison. The test results show that the control effectively reduced acceleration for short period motions with frequencies close to the predominant frequency of the structure, as well as effectively reduced displacement for long period motions with frequencies close to the natural frequency of the floor isolation system. The control algorithm proved to be more advantageous than passive control because of its capacity to adjust control strategies according to the different motion frequency characteristics.

关键词: semi-active     floor isolation     H control     MR damper     shaping filter     shaking table test    

电力系统主动支撑能源转型 Editorial

薛禹胜

《工程(英文)》 2021年 第7卷 第8期   页码 1035-1036 doi: 10.1016/j.eng.2021.07.002

Active-reactive power scheduling of integrated electricity-gas network with multi-microgrids

《能源前沿(英文)》 2023年 第17卷 第2期   页码 251-265 doi: 10.1007/s11708-022-0857-1

摘要: Advances in natural gas-fired technologies have deepened the coupling between electricity and gas networks, promoting the development of the integrated electricity-gas network (IEGN) and strengthening the interaction between the active-reactive power flow in the power distribution network (PDN) and the natural gas flow in the gas distribution network (GDN). This paper proposes a day-ahead active-reactive power scheduling model for the IEGN with multi-microgrids (MMGs) to minimize the total operating cost. Through the tight coupling relationship between the subsystems of the IEGN, the potentialities of the IEGN with MMGs toward multi-energy cooperative interaction is optimized. Important component models are elaborated in the PDN, GDN, and coupled MMGs. Besides, motivated by the non-negligible impact of the reactive power, optimal inverter dispatch (OID) is considered to optimize the active and reactive power capabilities of the inverters of distributed generators. Further, a second-order cone (SOC) relaxation technology is utilized to transform the proposed active-reactive power scheduling model into a convex optimization problem that the commercial solver can directly solve. A test system consisting of an IEEE-33 test system and a 7-node natural gas network is adopted to verify the effectiveness of the proposed scheduling method. The results show that the proposed scheduling method can effectively reduce the power losses of the PDN in the IEGN by 9.86%, increase the flexibility of the joint operation of the subsystems of the IEGN, reduce the total operation costs by $32.20, and effectively enhance the operation economy of the IEGN.

关键词: combined cooling     heating     and power (CCHP)     integrated energy systems (IES)     natural gas     power distribution system     gas distribution system    

A low power consumption control scheme: application to a piezostack-based active mount

T. LOUKIL, O. BAREILLE, M. N. ICHCHOU, M. HADDAR

《机械工程前沿(英文)》 2013年 第8卷 第4期   页码 383-389 doi: 10.1007/s11465-013-0274-6

摘要:

Piezostack-based active mounts have shown great efficiency for vibration control in a wide frequency range. In this paper, we investigate the performances of the global semi-active control strategy presented by Ichchou et al. [ ] for a control system consisting of an active mount and a supported mass. The control strategy allows extracting vibrations energy of the supported mass, storing it in accumulators to be reused for powering in part the actuators (two piezostacks). Consequently, energy needs are reduced versus good control performances comparable to those of the active control based on the negative velocity feedback. The performances of the controller are evaluated in both frequency (transmitted force) and time (acceleration) domains which show that vibrations of the supported mass due to base excitations are efficiently attenuated with the proposed law. An energetic analysis confirms the reduced energy requirement compared to the active scheme.

关键词: hybrid mount     energy     control     piezoelectric     harvesting    

Robust control based on the Lyapunov theory of a grid-connected doubly fed induction generator

Ridha CHEIKH, Arezki MENACER, Said DRID

《能源前沿(英文)》 2013年 第7卷 第2期   页码 191-196 doi: 10.1007/s11708-013-0245-y

摘要: This paper discusses the robust control of a grid-connected doubly-fed induction generator (DFIG) controlled by vector control using a nonlinear feedback linearization strategy in order to ameliorate the performances of the control and to govern the developed stator active and reactive power in a linear and decoupled manner, in which an optimal operation of the DFIG in sub-synchronous operation is given, as well as the control stator power flow with the possibility of keeping stator power factor at a unity. The use of the state-all-flux induction machine model gives place to a simpler control model. So, to achieve this objective, the Lyapunov approach is used associated with a sliding mode control to guarantee the global asymptotical stability and the robustness of the parametric variations.

关键词: doubly fed induction generator (DFIG)     vector control     Lyapunov function     power factor unity     active power     reactive power    

标题 作者 时间 类型 操作

Power quality improvement using fuzzy logic controller for five-level shunt active power filter under

Amar BENAISSA,Boualaga RABHI,Ammar MOUSSI

期刊论文

Rapid transaction to load variations of active filter supplied by PV system

M. BENADJA,S. SAAD,A. BELHAMRA

期刊论文

Robust switched fractional controller for performance improvement of single phase active power filter

H. AFGHOUL,F. KRIM,D. CHIKOUCHE,A. BEDDAR

期刊论文

A simple digital control algorithm for three phase shunt active filter: simulation and experimentation

Subbaraman SRINATH, Chandan KUMAR, M. P. SELVAN

期刊论文

基于迭代算法的有源电力滤波器谐波电流实时检测新方法

李自成,孙玉坤

期刊论文

Unified power quality conditioner based on a three-level NPC inverter using fuzzy control techniques

Salim CHENNAI,M-T BENCHOUIA

期刊论文

电流型有源电力滤波器的神经网络滞环控制

王萍,张珂,许会军

期刊论文

多模块并联有源电力滤波器系统及其基于分相控制和实时总线通讯的新型容错控制策略

Qun-wei XU, Jin-xiang ZHAN, Long XIAO, Guo-zhu CHEN

期刊论文

UPFC setting to avoid active power flow loop considering wind power uncertainty

Shenghu LI, Ting WANG

期刊论文

Performance of PI controller for control of active and reactive power in DFIG operating in a grid-connected

Azzouz TAMAARAT,Abdelhamid BENAKCHA

期刊论文

H control in the frequency domain for a semi-active floor isolation system

Yundong SHI, Tracy C BECKER, Masahiro KURATA, Masayoshi NAKASHIMA

期刊论文

电力系统主动支撑能源转型

薛禹胜

期刊论文

Active-reactive power scheduling of integrated electricity-gas network with multi-microgrids

期刊论文

A low power consumption control scheme: application to a piezostack-based active mount

T. LOUKIL, O. BAREILLE, M. N. ICHCHOU, M. HADDAR

期刊论文

Robust control based on the Lyapunov theory of a grid-connected doubly fed induction generator

Ridha CHEIKH, Arezki MENACER, Said DRID

期刊论文