Removal of non-point pollutants from bridge runoff by a hydrocyclone using natural water head

Jianghua YU, Yeonseok KIM, Youngchul KIM

《环境科学与工程前沿(英文)》 2013年 第7卷 第6期   页码 886-895 doi: 10.1007/s11783-012-0449-0

摘要: A hydrocyclone using natural water head provided by bridge was operated for the treatment of stormwater runoff. The hydrocyclone was automatically controlled using electronic valve which is connected to a pressure meter. Normally the hydrocyclone was open during dry days, but it was closed after the capture of the first flush. The results indicated that the average pressure and the flow rate were directly affected by the rainfall intensity. The pressure head was more than 2 m when the rainfall intensity was above 5 mm·h . The percentage volume of underflow with high solids concentration decreased as the pressure and flow rate increased, but the percentage volume of overflow with almost no solids showed the opposite behavior. The total suspended solids (TSS) concentration ratio between the overflow and inflow (TSS /TSS ) decreased as a function of the operational pressure, while the corresponding ratio of underflow to inflow (TSS /TSS ) increased. The TSS separation efficiency was evaluated based on a mass balance. It ranged from 25% to 99% with the pressure head ranging from 1.4 to 9.7 m, and it was proportional to pressure and flow rate. Normally, the efficiency was more than 50% when the pressure was higher than 2 m. The analysis of the water budget indicated that around 13% of the total runoff was captured by the hydrocyclone as a first flush, and this runoff was separated as underflow and overflow with the respective percentage volumes of 29% and 71%. The pollutants budget was also examined based on a mass balance. The results showed that the percentage of TSS, chemical oxygen demand (COD), total nitrogen (TN), and total phosphorus (TP) in underflow were 73%, 59%, 7.6%, and 49%, respectively. Thus, it can be concluded that the hydrocyclone worked well. It separated the first flush as solids-concentrated underflow and solids-absent overflow, and effectively reduced the runoff volume needing further treatment. Finally, four types of optional post treatment design are presented and compared.

关键词: first flush     hydrocyclone     non-point pollution     removal efficiency     stormwater runoff    

标题 作者 时间 类型 操作

Removal of non-point pollutants from bridge runoff by a hydrocyclone using natural water head

Jianghua YU, Yeonseok KIM, Youngchul KIM

期刊论文