Journal Home Online First Current Issue Archive For Authors Journal Information 中文版

Frontiers of Mechanical Engineering >> 2008, Volume 3, Issue 4 doi: 10.1007/s11465-008-0063-9

Precision control system of two-DOF stage with linear ultrasonic motor

Precision Driving Laboratory, Nanjing University of Aeronautics and Astronautics

Available online: 2008-12-05

Next Previous

Abstract

Using an appropriate control method, linear ultrasonic motors can be used in applications requiring high position accuracy. In this paper, a closed loop PI control system is designed to achieve high position accuracy during the control of a two-DOF stage driven by linear ultrasonic motors. Two ultrasonic motors are mounted on the stage to generate motion in two orthogonal directions. The PI control algorithm is used to increase the stability and accuracy of position control. The -axis mover covers 30 mm forward and backward in less than 0.3 s settling time and the -axis mover in less than 0.4 s. Experimental results denote that the control strategy proposed in this paper appears to have high efficiency, quick response, and high accuracy.