Journal Home Online First Current Issue Archive For Authors Journal Information 中文版

Frontiers of Structural and Civil Engineering >> 2019, Volume 13, Issue 5 doi: 10.1007/s11709-019-0542-6

Behavior and strength of headed stud shear connectors in ultra-high performance concrete of composite bridges

Key Laboratory of Concrete and Prestressed Concrete Structures of the Ministry of Education, School of Civil Engineering, Southeast University, Nanjing 211189, China

Accepted: 2019-06-06 Available online: 2019-06-06

Next Previous

Abstract

This study presents an experimental and numerical investigation on the static behavior of headed stud shear connectors in ultra-high performance concrete (UHPC) of composite bridges. Four push-out specimens were tested. It was found that no cracking, crushing or splitting was observed on the concrete slab, indicating that UHPC slab exhibited good performance and could resist the high force transferred from the headed studs. The numerical and experimental results indicated that the shear capacity is supposed to be composed of two parts stud shank shear contribution and concrete wedge block shear contribution. The stiffness increment of a stud in UHPC was at least 60% higher than that in normal strength concrete. Even if the stud height was reduced from 6 to 2 , there was no reduction in the shear strength of a stud. Short stud shear connectors with an aspect ratio as small as 2 could develop full strength in UHPC slabs. An empirical load-slip equation taking into account stud diameter was proposed to predict the load-slip response of a stud. The reliability and accuracy of the proposed load-slip equation was verified by the experimental and numerical load-slip curves.

Related Research