References
[ 1 ]
Kim A, Mawhinney J R, Su J.Water-mist system canreplace halon for use on electrical equipment[J].Canadian Consulting Engineer, 1996.30
[ 2 ]
NFPA.《750.Standard on Water Mist Fire ProtectionSystems》[S].2000 Edition.Quincy:National FireProtection Association, 2000
[ 3 ]
Mawhinney J R.Water-mist fire Suppression systems forthe telecommunication and utility industries[A].Proceedings:Halon Alternatives Technical WorkingConference[C].Albuquerque NM, 1994.395
[ 4 ]
Mawhinney J R.Findings of experiments using water mistfor fire suppression in an electronic equipment room[A].Proceedings:Halon Alternatives Technical WorkingConference[C].Albuquerque NM, 1994.395
[ 5 ]
Botting R E.Fire engineering and eesearch:fire detectionand protection of telephone exchange main distributionframes[A].Annual Conference of the Institution of FireEngineers[C].Telecom Corporation of New Zealand LtdNew Zealand Branch, 1990
[ 6 ]
Hills A T, Simpson T, Smith D P.Water mist mireprotection systems for telecommunication switch gear andother electronic eacilities[A].Proceedings:Water MistFire Suppression Workshop[C].USA, 1993.123~144
[ 7 ]
Simpson T, Smith D P.A fully integrated water mist firesuppression system for telecommunications and otherelectronics cabinets[A].International Conference onWater Mist Fire Suppression Systems[C].Boras Sweden, 1993
[ 8 ]
Liu Z, Kim A K.A Literature Review of Impact ofThermal Decomposition Products Generated by HalonReplacement on Electronic Equipment[R].IRC InternalReport 780.National Research Council of Canada, 1999
[ 9 ]
Carlzon B.Fire protection in computer room[A].NordicConference on Water Mist Applications[C].SwedishNational Testing and Research Institute, SP Report, 1997
[10]
Tuomisaari M.Smoking scrubbing in a computer room[A].Proceedings:Halon Alternatives Technical WorkingConference[C].Albuquerque NM, 1999.308
[11]
廖光煊, 周晓猛, 一种用于细水雾灭火的添加剂, 申请号:200310112793.8[S]
[12]
Grant G, Brenton J, Drysdale D.Fire suppression bywater sprays[J].Progress in Energy and CombustionScience.2000 (26) :79~130
[13]
Anthony D, Finnerty E.Water-based Fire-extinguishingAgents[M].U S Army Research Labortory, 1995.95~101
[14]
Gann R G.Next Generation Fire Suppression TechnologyProgram[M].National Institute of Standards andTechnology, 2000.1059
[15]
Grosshandler W, Lowe D.Protection of Data ProcessingEquipment with Fine Water Sprays[M].National Instituteof Standards and Technology.
[16]
刘江虹, 廖光煊, 厉培德.细水雾灭火技术研究与进展[J].科学通报, 2003, 48 (8) :761~767
link1
[17]
Mawhinney J R, Richardson J K.A review of water mistfire suppression research and development[J].FireTechnology, 1997, 33 (1) :54~90
link1
[18]
Liu Z, Kim A K.A review of water mist fire suppressionsystems-fundamental studies[J].Journal of Fire ProtectionEngineering, 2000, 10 (3) :32~50
[19]
房玉东, 廖光煊, 徐强, 周晓猛.含添加剂超细水雾作用下电气设备击穿强度实验研究[A].2004消防会议-整体安全理念vol3[C].香港, 2004
[20]
房玉东, 刘江虹, 廖光煊, 徐强.含MC添加剂超细水雾作用下电极击穿强度变化规律的实验研究.《科学通报》。2005, 50 (18) :2031~2036
link1
[21]
Fire Suppression Substitutes and Alternatives to Halon forU.S.Navy Applications[R].Commission on PhysicalSciences Mathematics and Applications (CPSMA) , 1997.
[22]
Mawhinney J R, DiNenno P J, Williams F W.Water MistFlashover Suppression and Boundary Cooling System forIntegration with DC-ARM[A].Volume 1:Summary ofTesting NRL/MR/6180-99-8400[S].1999
[23]
张晓燕, 郭强, 李全.微细水雾除尘技术的研究[J].环境污染与防治, 2003, 234~237
link1
[24]
张晓燕.微细水雾除尘系统设计及实验研究[J]。工业安全与环保, 2001, 1~4
[25]
陆强, 廖光煊, 黄鑫, 宛田宾.舰船细水雾灭火系统研究回顾[J].中国工程科学, 2004, 6 (9) :88~93
link1
[26]
Liu Z, Kim A K.A literature review of impact of thermaldecomposition products generated by Halon replacement onelectronic equipment[A].IRC Internal Report 780[C].National Research Council of Canada, 1999
[27]
崔正心, 廖光煊.细水雾抑制障碍物稳定火焰的实验研究[J].火灾科学.2001, 10 (3) :174~177
link1
[28]
King M, D, Wendy J C.Evaporation of a small waterdroplet containing an additive[A].Proceedings of theASME National Heat Transfer Conference[C].Baltimore, 1997
[29]
Anthony J, Bogdan H, Dlugogorski Z.Extinguishingmentof small scale poolfires with ultrafineparticles[A].HOTWC 96‘[C].1996
[30]
Madrzykowski D, Water addtives forincreased efficiency offire protection and suppression fire detection[A].FireExtinguishingment and Fire Safety Engineering NRIFD 50thAnniversary Symposium Proceedings[C], Japan, 1998
[31]
Cousin C S.The potential of fine water sprays as halonreplacements for fires in enclosures[A].InternationalConference on Water Mist Fire Suppression Systems[C].Sweden, 1993
[32]
Lewis R H.Aircraft cabin water fire suppression-where tonow[J].Fire Prevention.1994, 270:16~24
[33]
International Cabin Water Spray Research ManagementGroop.Conclusions of Research Program[R].CivilAviation Authority, 1993.CAA Paper 93012
[34]
Mawhinney J R, DiNenno P J, Williams F W.Using watermist for flashover suppression on navy ships[A].HalonAlternatives Technical Working Conference[C].Albuquerque, 1999.395~4