Journal Home Online First Current Issue Archive For Authors Journal Information 中文版

Strategic Study of CAE >> 2005, Volume 7, Issue 9

The Realization of Time-Triggered Control Area Network

1. School of Electrical and Automation Engineering, Tianjin University, Tianjin 300072, China

2. School of Electronic Information Engineering, Tianjin University, Tianjin 300072, China

Funding project:天津市重大攻关资助项目(023183611) Received: 2004-04-22 Revised: 2004-10-08 Available online: 2005-09-20

Next Previous

Abstract

The time-triggered architecture for CAN is analyzed. The implementation issue of time- triggered architecture based on 8052 single-chip processor and CAN controller SJA1000 is designed. The maximum number of transmission messages in basic cycle is given. And the scheduling capability is analyzed. The experiment is based on the automotive engine management, the result proves that using time-triggered architecture can not only manage the message transmission but also improve the bandwidth utilization.

Figures

图1

图2

图3

References

[ 1 ] Almeida L, Pedreiras P, Fonseca J A G.The FTT-CAN protocol:why and how[J].IEEE Transactionson Industrial Electronics, 2002, 49 (6) :1189~1201

[ 2 ] Zuberi K M, Shin K G.Non-preemptive scheduling ofmessage on controller area network for real-time controlapplications[A].Proc Real-Time Technology andApplications Symposium[C].1995.240~249

[ 3 ] Leen G, Heffernan D.TTCAN:a new time-triggeredcontroller area network[J].Microprocessors andMicrosystems, 2002, 26 (2) :77~94

[ 4 ] Hong-Hee Lee, Ui-Hurn Jeong.Design of distributedscheduler on CAN for real-time networking[A].Proceedings The Fifth Russian-Korean InternationalSymposium, No 3[C].2001.22~25

Related Research