Journal Home Online First Current Issue Archive For Authors Journal Information 中文版

Strategic Study of CAE >> 2006, Volume 8, Issue 6

Application of Double-Membrane Water Treatment Process in the Reuse System of Metallurgical Waste Water

Handan Iron and Steel ( Group) Co . Ltd . , Handan, Hebei 056015, China

Received: 2005-09-27 Available online: 2006-06-20

Next Previous

Abstract

The double-membrane(ultrafiltration and reverse osmosis) water treatment process features high quality of treated water, easy for realizing autocontrol, less land occupied, low water consumption, environmentally friendly, etc. The paper introduced the application of the double-membrane process in the reuse system of the waste water in Handan iron and Steel (Group) Co. Ltd.

Figures

图1

图2

图3

References

[ 1 ] 徐有生, 丁朝模.污水资源化是改善环境解决淡水资源短缺的重要途径[J].中国工程科学, 2005, 增刊, 112~116 link1

[ 2 ] 任建新.膜分离技术及其应用[M].北京:化学工业出版社, 2003 link1

[ 3 ] 冯逸仙, 杨世纯.反渗透水处理工程[M].北京:中国电力出版社, 2000 link1

[ 4 ] 上海市环境保护局.废水生化处理[M].上海:同济大学出版社, 1999 link1