Journal Home Online First Current Issue Archive For Authors Journal Information 中文版

Strategic Study of CAE >> 2007, Volume 9, Issue 4

Study on Temperature Control of Trace ContaminantControl Subassembly in Manned Spacecraft

Haiyan County, Zhejiang Province, 314300, China

Funding project:第三十八批博士后科学基金资助项目 Received: 2006-03-16 Revised: 2006-05-18

Next Previous

Abstract

The catalytic oxidizer assembly(COA)is an important part of the trace contaminant control subassembly in manned spacecraft. Temperature control in COA via a new self-tuning fuzzy logical controller (FLC)is analyzed in this paper. The new tuning method applies the bang-bang on-line tuned method to the design of the self-tuning FLC for obtaining the system parameters. On the basis of these parameters, the input and output scaling factors are calculated with simple tunable formulas. Then the proposed self-tuning FLC is realized by combining the scaling factors and the normal look-up table. It can realize self-tuning parameters,  and simplify the design. Simulation results show that the proposed self-tuning FLC is fit for controlling the temperature of COA and isn't sensitive to parameter changes.

Figures

图 1

图 2

图 3

图 4

图 5

图 6

References

[ 1 ] Perry J L , Franks G D . International Space Station Program Phase III Integrated Atmosphere Revitalization Subsystem Test Final Report [R] . NASA T/M - 1997 - 108541 ,1997 .12 ~ 15

[ 2 ] Ray C D ,Salyer B H . International Space Station ECLSS Technical Task Agreement Summary Report [R] .NASA/TM - 1999 - 209573 ,1999 .99 ~ 112

[ 3 ] Li Hongxing ,Chen C L Philip .Relationship between fuzzy controllers and PID controllers [A] . Proceedings of the 1999 IEEE/RSJ , International Conference on Intelligent Robots and Systems ,1999 .94 ~ 99

[ 4 ] Alonge F . Method for designing PI-type fuzzy controllers for induction motor drives [J] . IEE Proc-control Theory Appl ,2001 ,148 (1) :61 ~ 68 link1

[ 5 ] Lee J . One method for improving performance of PI-type fuzzy logic controllers [J] .IEEE Trans Fuzzy Syst ,1993 , (1) :298 ~ 301 link1

[ 6 ] Jung C H , Ham C S . A real-time self-tuning fuzzy controller through scaling factor adjustment for the steam generator of NPP [J] .Fuzzy Sets and Systems ,1995 ,74 : 53 ~ 60 link1

[ 7 ] Mudi R K . A robust self-tuning scheme for PI- and PD- type fuzzy controllers [J] . IEEE Transactions on Fuzzy Systems ,1999 ,7(1) :2 ~ 15 link1

[ 8 ] 谢新民 .自适应控制系统 [M] .北京 :清华大学出 版社 ,2002 .151 ~ 161

Related Research