Journal Home Online First Current Issue Archive For Authors Journal Information 中文版

Frontiers of Environmental Science & Engineering >> 2019, Volume 13, Issue 2 doi: 10.1007/s11783-019-1105-8

Influence of pore size and membrane surface properties on arsenic removal by nanofiltration membranes

State Key Joint Laboratory of Environmental Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, China

Available online: 2019-02-22

Next Previous

Abstract

Four NF membranes were compared regarding arsenate rejection and their properties.

Rejection of arsenate had no relationship with membrane pore size.

A more negative surface charge was favorable for arsenate rejection at neutral pH.

A severe membrane fouling could lead to a great reduction of arsenic rejection.