FY-3B卫星微波湿度计热真空定标方法和结果分析

王振占,张升伟,李靖,李芸,吴琼

中国工程科学 ›› 2013, Vol. 15 ›› Issue (10) : 33 -46.

PDF (2898KB)
中国工程科学 ›› 2013, Vol. 15 ›› Issue (10) : 33 -46.

FY-3B卫星微波湿度计热真空定标方法和结果分析

作者信息 +

Thermal/vacuum calibration of microwave humidity sounder on FY-3B satellite

Author information +
文章历史 +
PDF (2966K)

摘要

本文论述了风云三号卫星B星微波湿度计(MWHS-3B)发射前热真空定标的原理和方法,建立了各种定标误差的修正算法,获得了MWHS-3B的系统线性度、观测不同目标的灵敏度和最终定标精度等关键技术指标。这些参数已经用于MWHS-3B在轨数据的处理。

Abstract

The principle and methods on thermal/vacuum (T/V) testing of microwave humidity sounder (MWHS) on FY-3B satellite were described; correction algorithms on calibration errors were developed, and some main specifications of MWHS-3B, such as linearity, sensitivity and calibration precision, were obtained. The parameters derived from the T/V testing had been used in in-orbit data processing to produce brightness temperature products in FY-3B ground system.

关键词

风云三号卫星 / 微波湿度计 / 发射前定标 / 热真空定标

Key words

FY-3B satellite / microwave humidity sounder / prelaunch calibration / thermal/vacuum testing

Author summay

王振占(1969—),男,河北青龙县人,研究员,博士生导师,主要研究方向为微波遥感新技术及应用技术

引用本文

引用格式 ▾
王振占,张升伟,李靖,李芸,吴琼 FY-3B卫星微波湿度计热真空定标方法和结果分析[J]. 中国工程科学, 2013, 15(10): 33-46 DOI: