太湖流域印染废水为主的城镇污水处理厂提标技术研究

吴海锁,许明,张敏健,刘伟京,喻学敏,吴伟

中国工程科学 ›› 2010, Vol. 12 ›› Issue (6) : 54 -59.

PDF (986KB)
中国工程科学 ›› 2010, Vol. 12 ›› Issue (6) : 54 -59.

太湖流域印染废水为主的城镇污水处理厂提标技术研究

作者信息 +

Research on standard upgrading technologies of urban wastewater treatment plants for pollutions dominated by printing and dyeing wastewater in Taihu Lake Basin

Author information +
文章历史 +
PDF (1009K)

摘要

采用调节—厌氧水解—A/O(PACT)—高效澄清池—过滤组合工艺处理综合印染废水。开展了中试试验研究和示范工程研究,研究结果表明:中试系统运行稳定,对COD、色度、氨氮、总氮、总磷平均去除率分别为93.2 %,93.9 %,90.2 %,70.8 %,96.3 %;厌氧COD平均去除率分别为48.1 %;色度平均去除率分别为75.7 %;A/O(PACT)工艺对氨氮和总氮的去除效果明显,混凝沉淀工艺则对总磷去除效果最理想;中试研究和示范工程出水水质稳定,各项指标均满足《太湖地区城镇污水处理厂及重点工业行业主要水污染物排放限值》(DB32/1072-2007)。

Abstract

Pilot-scale & demonstration project study of the treatment of printing and dyeing wastewater was carried out using the combined process of anaerobic (hydrolysis)-aerobic-advanced treatment. The result of Pilot-scale study indicates:the total removal efficiency of the COD, color, NH3-N, TN, TP of the system were 93.2 %, 93.9 %, 90.2 %, 70.8 %, 96.3 % respectively, anaerobic (hydrolysis) is vital to COD & color degradation, the removal efficiency of the COD & color were 48.1 %, 75.7 %, respectively, The A/O(PACT)is vital to NH3-N & TN degradation, the coagulation treatment could effectively degrade the TP. The effluent of Pilot-scale & demonstration project could satisfy 《Discharge Standard of Main Water Pollutants for Municipal Wastewater Treatment Plant & Key Industries of Taihu Area》(DB32/1072-2007).

关键词

太湖流域 / 印染废水 / 脱氮除磷 / 示范工程

Key words

Taihu Area / printing and dyeing wastewater / nitrogen and phosphorus removal / demonstration project

Author summay

吴海锁(1963-),男,江苏海安市人,博士,江苏省环境科学研究院研究员级高级工程师,主要从事水污染控制工程工作

引用本文

引用格式 ▾
吴海锁,许明,张敏健,刘伟京,喻学敏,吴伟 太湖流域印染废水为主的城镇污水处理厂提标技术研究[J]. 中国工程科学, 2010, 12(6): 54-59 DOI: