Engineering in Situ Cu Electrodeposition and Ionization in the LEEFT-Cu System with a Stainless-Steel/Cu Core-Shell Electrode for Extended Water Disinfection

Wei Wang , Feiyang Mo , Mengkun Tian , Shuai Wang , Nathan Dong , Xing Xie

Engineering ›› : 202601016

PDF (2806KB)
Engineering ›› :202601016 DOI: 10.1016/j.eng.2026.01.016
Research
research-article
Engineering in Situ Cu Electrodeposition and Ionization in the LEEFT-Cu System with a Stainless-Steel/Cu Core-Shell Electrode for Extended Water Disinfection
Author information +
History +
PDF (2806KB)

Abstract

Combining locally enhanced electric field treatment with copper disinfection (LEEFT-Cu) in coaxial-electrode copper ionization cells has shown effective microbial inactivation with low Cu concentration. However, a significant challenge remains with the current device design using a thin Cu wire as the cen-ter electrode. Continuous consumption of the center Cu electrode requires periodic system shutdown and disassembly for electrode replacement, while pitting corrosion of the electrode results in low Cu utiliza-tion efficiency. These issues restrict its suitability for long-term operation. Herein, we report the use of a stainless-steel/Cu core-shell (SS@Cu) wire electrode as a more durable alternative. The non-consumable SS core effectively prevents system failure due to breakdown of the center electrode and enables near-complete Cu release (∼ 100%). More importantly, the Cu shell is formed and regenerated directly within the LEEFT-Cu device through in situ Cu electrodeposition, avoiding the need for frequent system shut-down and wire replacement. The system operates in cycles of ∼ 25 h with only about half an hour required for SS@Cu electrode regeneration. These findings highlight the potential of the LEEFT-Cu system for extended operation in practical water disinfection.

Keywords

Chlorine-free disinfection / Electric field treatment / Copper ionization cell / Microbial inactivation / Electroporation

Cite this article

Download citation ▾
Wei Wang, Feiyang Mo, Mengkun Tian, Shuai Wang, Nathan Dong, Xing Xie. Engineering in Situ Cu Electrodeposition and Ionization in the LEEFT-Cu System with a Stainless-Steel/Cu Core-Shell Electrode for Extended Water Disinfection. Engineering 202601016 DOI:10.1016/j.eng.2026.01.016

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Greenwood EE, Lauber T, van den Hoogen J, Donmez A, Bain RES, Johnston R, et al. Mapping safe drinking water use in low-and middle-income countries. Science 2024; 385(6710):784-90.

[2]

Pons W, Young I, Truong J, Jones-Bitton A, McEwen S, Pintar K, et al. A systematic review of waterborne disease outbreaks associated with small non-community drinking water systems in Canada and the United States. PLoS One 2015; 10(10):0141646.

[3]

Kunz JM, Lawinger H, Miko S, Gerdes M, Thuneibat M, Hannapel E, et al. Surveillance of waterborne disease outbreaks associated with drinking water— United States, 2015-2020. MMWR Surveill Summ 2024; 73(1):1-23.

[4]

Wang W, Kang S, Zhou W, Vikesland PJ. Environmental routes of virus transmission and the application of nanomaterial-based sensors for virus detection. Environ Sci Nano 2023; 10(2):393-423.

[5]

Cai Y, Sun T, Li G, An T. Traditional and emerging water disinfection technologies challenging the control of antibiotic-resistant bacteria and antibiotic resistance genes. ACS ES T Eng 2021; 1(7):1046-64.

[6]

Gao R, Gao SH, Li J, Su Y, Huang F, Liang B, et al. Emerging technologies for the control of biological contaminants in water treatment: a critical review. Engineering 2025;48:185-204.

[7]

Allen JM, Plewa MJ, Wagner ED, Wei X, Bokenkamp K, Hur K, et al.Drivers of disinfection byproduct cytotoxicity in US drinking water: should other DBPs be considered for regulation? Environ Sci Technol 2022; 56(1):392-402.

[8]

Freuze I, Brosillon S, Laplanche A, Tozza D, Cavard J. Effect of chlorination on the formation of odorous disinfection by-products. Water Res 2005; 39 (12):2636-42.

[9]

Liu S, Gunawan C, Barraud N, Rice SA, Harry EJ, Amal R. Understanding, monitoring, and controlling biofilm growth in drinking water distribution systems. Environ Sci Technol 2016; 50(17):8954-76.

[10]

Dotson AD, Rodriguez CE, Linden KG.UV disinfection implementation status in US water treatment plants. J Am Water Works Assoc 2012; 104(5):E318-24.

[11]

Morrison CM, Hogard S, Pearce R, Gerrity D, von Gunten U, Wert EC. Ozone disinfection of waterborne pathogens and their surrogates: a critical review. Water Res 2022;214:118206.

[12]

Song Y, Pruden A, Edwards MA, Rhoads WJ. Natural organic matter, orthophosphate, pH, and growth phase can limit copper antimicrobial efficacy for Legionella in drinking water. Environ Sci Technol 2021; 55 (3):1759-68.

[13]

Salah I, Parkin IP, Allan E. Copper as an antimicrobial agent: recent advances. RSC Adv 2021; 11(30):18179-86.

[14]

Park HJ, Nguyen TT, Yoon J, Lee C. Role of reactive oxygen species in Escherichia coli inactivation by cupric ion. Environ Sci Technol 2012; 46(20):11299-304.

[15]

Ramos-Zúñiga J, Bruna N, Pérez-Donoso JM. Toxicity mechanisms of copper nanoparticles and copper surfaces on bacterial cells and viruses. Int J Mol Sci 2023; 24(13):10503.

[16]

Sharan R, Chhibber S, Reed RH. Inactivation and sub-lethal injury of Salmonella typhi, Salmonella typhimurium and Vibrio cholerae in copper water storage vessels. BMC Infect Dis 2011; 11(1):204.

[17]

Ben-Sasson M, Zodrow KR, Genggeng Q, Kang Y, Giannelis EP, Elimelech M.Surface functionalization of thin-film composite membranes with copper nanoparticles for antimicrobial surface properties. Environ Sci Technol 2014; 48(1):384-93.

[18]

Grass G, Rensing C, Solioz M. Metallic copper as an antimicrobial surface. Appl Environ Microbiol 2011; 77(5):1541-7.

[19]

Mo F, Zhou J, Yu C, Liu F, Jumili M, Wu Y, et al. Decou pling locally enhanced electric field treatment (LEEFT) intensity and copper release b y applying asymmetric electric pulses for water disinfection. Water Res X 2023;21:100206.

[20]

Allen JM, Plewa MJ, Wagner ED, Wei X, Bollar GE, Quirk LE, et al. Making swimming pools safer: does copper-silver ionization with chlorine lower the toxicity and disinfection byproduct formation? Environ Sci Technol 2021; 55 (5):2908-18.

[21]

Cachafeiro SP, Naveira IM, García IG. Is copper-silver ionisation safe and effective in controlling legionella? J Hosp Infect 2007; 67(3):209-16.

[22]

Triantafyllidou S, Lytle D, Muhlen C, Swertfeger J.Copper-silver ionization at a US hospital: interaction of treated drinking water with plumbing materials, aesthetics and other considerations. Water Res2016;102:1-10.

[23]

LeChevallier M. Examining the efficacy of copper-silver ionization for management of Legionella : recommendations for optimal use. AWWA Water Sci 2023; 5(2):e1327.

[24]

Jarin M, Wang T, Xie X. Operando investigation of the synergistic effect of electric field treatment and copper for bacteria inactivation. Nat Commun 2024; 15(1):1345.

[25]

Jakstys B, Jakutaviciute M, Uzdavinyte D, Satkauskiene I, Satkauskas S. Correlation between the loss of intracellular molecules and cell viability after cell electroporation. Bioelectrochemistry 2020;135:107550.

[26]

Zhou J, Hung YC, Xie X. Making waves: pathogen inactivation by electric field treatment: from liquid food to drinking water. Water Res 2021;207:117817.

[27]

Kim YJ, Huo ZY, Wang X, Dai H, Lee DM, Suh IY, et al. Walking-induced electrostatic charges enable in situ electroporated disinfection in portable water bottles. Nat Water 2024; 2(4):360-9.

[28]

Huo ZY, Kim YJ, Suh IY, Lee DM, Lee JH, Du Y, et al. Triboelectrification induced self-powered microbial disinfection using nanowire-enhanced localized electric field. Nat Commun 2021; 12(1):3693.

[29]

Xu JX, Chen GQ, Chen YL, Wu HM, Chen D, Liu H. Nanowire-assisted electroporation via inducing cell destruction for inhibiting formation of VBNC bacteria: comparison with chlorination. Water Res 2024;258:121776.

[30]

Pi SY, Wang Y, Lu YW, Liu GL, Wang DL, Wu HM, et al. Fabrication of polypyrrole nanowire arrays-modified electrode for point-of-use water disinfection via low-voltage electroporation. Water Res 2021;207:117825.

[31]

Saraeva I, Zayarny D, Tolordava E, Nastulyavichus A, Khmelnitsky R, Khmelin D, et al. coli : TEM, Locally enhanced electric field treatment of E. FT-IR and Raman spectrometry study. Chemosensors 2023; 11(7):361.

[32]

Yue L, Chen S, Wang S, Wang C, Hao X, Cheng YF. Water disinfection using Ag nanoparticle-CuO nanowire co-modified 3D copper foam nanocomposites in high flow under low voltages. Environ Sci Nano 2019; 6(9):2801-9.

[33]

Wang S, Wang W, Yue L, Cui S, Wang H, Wang C, et al. Hierarchical Cu 2 O nanowires covered by silver nanoparticles-doped carbon layer supported on Cu foam for rapid and efficient water disinfection with lower voltage. Chem Eng J 2020;382:122855.

[34]

Wang T, Xie X. Nanosecond bacteria inactivation realized by locally enhanced electric field treatment. Nat Water 2023; 1(1):104-12.

[35]

Kumar P, Dhar A, Vaish R. Hand-powered and portable water disinfection system by locally enhanced electric field treatment (LEEFT) with modified nanowire electrodes. Eur Phys J Plus 2022; 137(6):709.

[36]

Huo ZY, Wang X, Huang X, Elimelech M. Intensifying electrified flow-through water treatment technologies via local environment modification. Front Environ Sci Eng 2024; 18(6):69.

[37]

Suh IY, Huo ZY, Jung JH, Kang D, Lee DM, Kim YJ, et al. Highly efficient microbial inactivation enabled by tunneling charges injected through two-dimensional electronics. Sci Adv 2024; 10(18):eadl5067.

[38]

Ding W, Zhou J, Cheng J, Wang Z, Guo H, Wu C, et al. TriboPump: a low-cost, hand-powered water disinfection system. Adv Energy Mater 2019; 9 (27):1901320.

[39]

Zhou J, Wang T, Xie X. Rationally designed tubular coaxial-electrode copper ionization cells (CECICs) harnessing non-uniform electric field for efficient water disinfection. Environ Int 2019;128:30-6.

[40]

Tripathi A, Park J, Pho T, Champion JA. Dual antibacterial properties of copper-coated nanotextured stainless steel. Small 2024; 20(38):2311546.

[41]

Zhang X, Yang C, Xi T, Zhao J, Yang K. Surface roughness of Cu-bearing stainless steel affects its contact-killing efficiency by mediating the interfacial interaction with bacteria. ACS Appl Mater Interfaces 2021; 13(2):2303-15.

[42]

Tripathi A, Dosso C, Champion JA. Antifungal activity of electrochemically etched nanotextured stainless steel against Candida albicans and Fusarium oxysporum fungal cells. ACS Omega 2025; 10(19):19326-34.

[43]

Ju X, Xiong P, Yan Z, Chen G, Cai C, Zhang R. Emergence of carbapenem-resistant Citrobacter spp. across human, animal, and water environments in China. Int J Antimicrob Agents 2025; 65(5):107463.

[44]

Faria C, Vaz-Moreira I, Serapicos E, Nunes OC, Manaia CM. Antibiotic resistance in coagulase negative staphylococci isolated from wastewater and drinking water. Sci Total Environ 2009; 407(12):3876-82.

[45]

de la Peña F, Prestat E, Fauske VT, Lähnemann J, Burdet P, Jokubauskas P, et al. HyperSpy/hyperspy: v2.1.1 [Internet]. Geneva: Zenodo; 2024 Jul 11 [cited 2026 Jan 22]. Available from: https://zenodo.org/records/12724131.

[46]

Tapiero H, Tew KD. Trace elements in human physiology and pathology: zinc and metallothioneins. Biomed Pharmacother 2003; 57(9):399-411.

[47]

Tan Y. Understanding the effects of electrode inhomogeneity and electrochemical heterogeneity on pitting corrosion initiation on bare electrode surfaces. Corros Sci 2011; 53(5):1845-64.

[48]

Kaur J, Khanna A, Kumar R, Chandra R. Growth and chara cterization of Cu 2 O and CuO thin films. J Mater Sci Mater Elect ron 2022; 33 (20):16154-66.

[49]

Tripathi A, Styczynski MP. Copper nanocubes as low-cost enzyme mimics in a sarcosine-sensing reaction cascade. Analyst 2025; 150(7):1248-60.

[50]

Feng Y, Siow KS, Teo WK, Tan KL, Hsieh AK. Corrosion mechanisms and products of copper in aqueous solutions at various pH values. Corrosion 1997; 53(5):389-98.

[51]

Feng Y, Teo WK, Siow KS, Tan KL, Hsieh AK. The corrosion b ehaviour of copper in neutral tap water. Part I: corrosion mechanisms. Corros Sci 1996; 38(3):369-85.

[52]

Kear G, Barker B, Walsh F. Electrochemical corrosion of unalloyed copper in chloride media--a critical review. Corros Sci 2004; 46(1):109-35.

[53]

Tsai KL, Chen CM, Ho CE. Synergistic effects of additives on impurity residues in high-speed copper electrodeposition and voiding propensity in solder joints. J Taiwan Inst Chem Eng 2024;156:105391.

PDF (2806KB)

20

Accesses

0

Citation

Detail

Sections
Recommended

/