期刊首页 优先出版 当期阅读 过刊浏览 作者中心 关于期刊 English

《结构与土木工程前沿(英文)》 >> 2015年 第9卷 第2期 doi: 10.1007/s11709-015-0296-8

Experimental and statistical investigation of a new concrete-composite beam with encased polymer tube wrapped by FRP

Laboratory LaMoMS, the University Mouloud Mammeri of Tizi Ouzou, Tizi Ouzou 15000, Algeria

录用日期: 2015-06-16 发布日期: 2015-06-30

下一篇 上一篇

摘要

A new concrete-composite beam with high mechanical performances to weight ratio is developed in this study. The proposed design technique consists to embed a cylindrical polymer tube wrapped by a GFRP Jacket in the mechanically ineffective concrete tensile zone. An experimental investigation is carried out on composite beams under bending loads until failure to evaluate the flexural capacity and the corresponding failure mechanisms. Based on the experimental results, statistical and preliminary reliability analyses using the FORM method are performed to assess the safety margin of the new beam. The confrontation between test and simulation results shows a satisfactory agreement, and represents a promising revelation regarding the improvement in terms of strength and ductility of such design compared to conventional reinforced concrete beams with traditional one.

相关研究