Study on Key Technologies of Passive Containment Heat Removal System for HPR1000

Ji Xing , Li Gao , Feng Liu , Zhongning Sun , Li Li , Xinli Yu , Yawei Mao , Haozhi Bian , Zhaoming Meng , Ming Ding

Engineering ›› 2025, Vol. 52 ›› Issue (9) : 204 -216.

PDF (3910KB)
Engineering ›› 2025, Vol. 52 ›› Issue (9) :204 -216. DOI: 10.1016/j.eng.2025.03.034
Research
Review

Study on Key Technologies of Passive Containment Heat Removal System for HPR1000

Author information +
History +
PDF (3910KB)

Abstract

The passive containment heat removal system (PCS) is one of the key passive safety systems of China’s third-generation advanced pressurized water reactor—Hua-long Pressurized Reactor (HPR1000), used to prevent overpressure of large concrete containment under severe accident scenarios. This paper provides an overview of the development of the HPR1000 passive containment heat removal system, including its operating principles and configuration, internal heat exchanger design, feasibility tests, engineering-scale PCS verification tests, comprehensive tests on PCS-containment coupling characteristics, among other key supporting studies. These extensive studies demonstrated that the PCS of HPR1000, which is designed based on flashing-driven open natural circulation and efficient condensation heat transfer theory, can work effectively and ensure the integrity of the containment under various accident scenarios. The system has been applied to Fuqing No. 5 and No. 6 nuclear power units and Zhangzhou No. 1 and No. 2 units of China’s first million-kilowatt third-generation nuclear power HPR1000. It is also applied to K-2/K-3 units of Karachi Nuclear Power Plant in Pakistan.

Keywords

Passive containment heat removal system / HPR1000 / Open natural circulation system / Severe accident / Thermal hydraulics

Cite this article

Download citation ▾
Ji Xing, Li Gao, Feng Liu, Zhongning Sun, Li Li, Xinli Yu, Yawei Mao, Haozhi Bian, Zhaoming Meng, Ming Ding. Study on Key Technologies of Passive Containment Heat Removal System for HPR1000. Engineering, 2025, 52(9): 204-216 DOI:10.1016/j.eng.2025.03.034

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Yanez J, Kuznetsov M, Souto-Iglesias A. An analysis of the hydrogen explosion in the Fukushima Daiichi accident. Int J Hydrogen Energy 2015; 40 (25):8261-80.

[2]

Luangdilok W. The explosions at Fukushima Daiichi Unit 3 and Unit 4 and implications on the evaluation of 1F3 accident. Nucl Eng Des 2020; 362:110536.

[3]

Saghafi M, Ghofrani MB. Accident management support tools in nuclear power plants: a post-Fukushima review. Prog Nucl Energy 2016; 92:1-14.

[4]

Dimmelmeier H, Eyink J, Movahed MA. Computational validation of the EPRTM combustible gas control system. Nucl Eng Des 2012; 249:118-24.

[5]

Zheng M, Yan J, Jun S, Tian L, Wang X, Qiu Z. The general design and technology innovations of CAP1400. Engineering 2016; 2(1):97-102.

[6]

Chang H, Lu Y, Wang Y, Liu L, Chang L, Wang Y, et al. Experimental study of the water film coverage and the delay time on water distribution phenomenon in PCS of CAP1400. Prog Nucl Energy 2017; 96:49-55.

[7]

Estévez-Albuja S, Fernández-Cosials K, Vázquez-Rodríguez C, Goñi-Velilla Z, Jiménez G. AP1000 passive containment cooling system study under LBLOCA conditions using the GOTHIC code. Nucl Eng Des 2021; 384:111442.

[8]

Xing J, Song D, Wu Y. HPR1000: advanced pressurized water reactor with active and passive safety. Engineering 2016; 2(1):79-87.

[9]

Lee SW, Baek WP, Chang SH. Assessment of passive containment cooling concepts for advanced pressurized water reactors. Ann Nucl Energy 1997; 24 (6):467-75.

[10]

Ha H, Lee S, Kim H. Optimal design of passive containment cooling system for innovative PWR. Nucl Eng Technol 2017; 49(5):941-52.

[11]

Jeon BG, No HC. Conceptual design of passive containment cooling system with air holdup tanks in the concrete containment of improved APR+. Nucl Eng Des 2014; 267:180-8.

[12]

Bang J, Jerng DW, Kim H. Comparisons of performance and operation characteristics for closed- and open-loop passive containment cooling system design. Nucl Eng Technol 2021; 53(8):2499-508.

[13]

Kim KM, Lee DH, Bang IC. Analysis of natural circulation behaviors and flow instabilities of passive containment cooling system design for advanced PWR using MARS-KS code. Int J Heat Mass Transf 2020; 147:118982.

[14]

Kyung IS, Lee SY. Experimental observations on flow characteristics in an open two-phase natural circulation loop. Nucl Eng Des 1994; 150(1):163-76.

[15]

Kyung IS, Lee SY. Periodic flow excursion in an open two-phase natural circulation loop. Nucl Eng Des 1996; 162(2-3):233-44.

[16]

Bang J, Hwang JH, Kim HG, Jerng DW. Parametric analyses for the design of a closed-loop passive containment cooling system. Nucl Eng Technol 2021; 53 (4):1134-45.

[17]

Dehbi AA, Golay MW, Kazimi MS. Condensation experiments in steam-air and steam-air-helium mixtures under turbulent natural convection. In:Proceedings of National Heat Transfer Conference; 1991 Jul 28-31; Minneapolis, MN, USA. American Institute of Aeronautics and Astronautics; 1991.

[18]

Dehbi A. Development of a general correlation for free convection vapor condensation over a horizontal tube in the presence of a noncondensable gas. Int Commun Heat Mass Transf 2021; 123:105210.

[19]

Park IW, Yang SH, Lee YG. Effect of light gas on condensation heat transfer of steam-air mixture and gas stratification. Int J Heat Mass Transf 2021; 179:121716.

[20]

Park IW, Yang SH, Lee YG. Degradation of condensation heat transfer on a vertical cylinder by a light noncondensable gas mixed with air-steam mixtures. Int Commun Heat Mass Transf 2022; 130:105779.

[21]

Kang J, Moon J, Ko Y, Lim SG, Yun B. Steam condensation on tube-bundle in presence of non-condensable gas under free convection. Int J Heat Mass Transf 2021; 178:121619.

[22]

Xing J, Sun Z, Ding M. HPR1000 passive containment heat removal system. J Harbin Eng Unive 2023; 44(7):1089-95. Chinese.

[23]

Su J, Sun Z, Zhang D. Numerical analysis of steam condensation over a vertical surface in presence of air. Ann Nucl Energy 2014; 72:268-76.

[24]

Su J, Sun Z, Ding M, Fan G. Analysis of experiments for the effect of noncondensable gases on steam condensation over a vertical tube external surface under low wall subcooling. Nucl Eng Des 2014; 278:644-50.

[25]

Tong P, Fan G, Sun Z, Ding M, Su J. An experimental investigation of pure steam and steam-air mixtures condensation outside a vertical pin-fin tube. Exp Therm Fluid Sci 2015; 69:141-8.

[26]

Fan G, Tong P, Sun Z, Chen Y. Experimental study of pure steam and steam-air condensation over a vertical corrugated tube. Prog Nucl Energy 2018; 109:239-49.

[27]

Bian H, Sun Z, Ding M, Zhang N, Meng Z. Application and evaluation of automatic wall treatment on diffusion boundary layer based steam condensation model in presence of air. In:Proceedings of 17th International Topical Meeting on Nuclear Reactor Thermal Hydraulics;2017 Sep 3-8; Xi’an, China. 2017.

[28]

Bian H, Sun Z, Ding M, Zhang N. Local phenomena analysis of steam condensation in the presence of air. Prog Nucl Energy 2017; 101:188-98.

[29]

Niu Z, Cheng J, Li W, Fan G. Experimental study of steam and steam-air mixture condensation over vertical chrome-plated tube and polished tube exterior surface. Nucl Eng Des 2021; 373:111029.

[30]

Cao B, Li Y, Sun Y, Bian H, Ding M. Experimental investigation of tube diameter and inclination angle on steam condensation accompanying with air in tube bundles. Ann Nucl Energy 2022; 166:108695.

[31]

Li G, Cao B, Zhou S, Bian H, Ding M. Effects of inclination and flow velocity on steam condensation consisting of air on tube bundle external surfaces. Prog Nucl Energy 2021; 136:103722.

[32]

Liu F, Sun Z, Cao B, Bian H, Ding M. Numerical investigations on the component separation phenomenon and transport behavior of steam-air-hydrogen mixture induced by condensation. Int J Therm Sci 2022; 172:107369.

[33]

Zhou S, Gao L, Jing R, Yang P, Bian H, Ding M. Research on a two-phase condensation model with predictable turbulent film. Prog Nucl Energy 2023; 163:104808.

[34]

Bian H, Sun Z, Cheng X, Zhang N, Meng Z, Ding M. CFD evaluations on bundle effects for steam condensation in the presence of air under natural convection conditions. Int Commun Heat Mass Transf 2018; 98:200-8.

[35]

Bian H, Lu Y, Li C, Liang T, Ding M. Comprehensive parameter analyses on steam-air condensation at pressures up to 1.6 MPa. Nucl Eng Des 2021; 385:111536.

[36]

Cao B, Li Y, Lu Y, Zhou S, Bian H, Ding M. Experimental study of air-steam condensation on the influence of tube diameter and inclination angle. Nucl Eng Des 2021; 381:111357.

[37]

Dehbi A. A generalized correlation for steam condensation rates in the presence of air under turbulent free convection. Int J Heat Mass Transf 2015; 86:1-15.

[38]

Fan G, Tong P, Sun Z, Chen Y. Development of a new empirical correlation for steam condensation rates in the presence of air outside vertical smooth tube. Ann Nucl Energy 2018; 113:139-46.

[39]

Su J, Sun Z, Fan G, Ding M. Experimental study of the effect of non-condensable gases on steam condensation over a vertical tube external surface. Nucl Eng Des 2013; 262:201-8.

[40]

Qu X, Sun Z, Ding M. Study on effect of header match on flow distribution in Utype arrangement parallel manifold of heat exchanger. At Energy Sci Technol 2015; 49(4):623-8. Chinese.

[41]

Zhou J, Sun Z, Ding M, Bian H, Zhang N, Meng Z. CFD simulation for flow distribution in manifolds of central-type compact parallel flow heat exchangers. Appl Therm Eng 2017; 126:670-7.

[42]

Zhou J, Ding M, Bian H, Zhang Y, Sun Z. CFD simulation for the effect of the header match on the flow distribution in a central-type parallel heat exchanger. Chem Eng Res Des 2018; 136:144-53.

[43]

Zhou J, Ding M, Bian H, Zhang Y, Sun Z. Characteristics of flow distribution in central-type compact parallel flow heat exchangers with modified inlet and header. Appl Therm Eng 2020; 166:114636.

[44]

Marcel CP, Rohde M, Van Der Hagen THJJ. Experimental and numerical investigations on flashing-induced instabilities in a single channel. Exp Therm Fluid Sci 2009; 33(8):1197-208.

[45]

Jiang SY, Yao MS, Bo JH, Wu SR. Experimental simulation study on start-up of the 5 MW nuclear heating reactor. Nucl Eng Des 1995; 158(1):111-23.

[46]

Furuya M, Inada F, Van Der Hagen THJJ. Flashing-induced density wave oscillations in a natural circulation BWR—mechanism of instability and stability map. Nucl Eng Des 2005; 235(15):1557-69.

[47]

Guo X, Sun Z, Wang J, Yu S. Simulating investigations on the start-up of the open natural circulation system. Nucl Eng Des 2015; 289:35-48.

[48]

Guo X, Sun Z, Wang J, Yu S. Scaling analyses for the open flashing-driven natural circulation system. Nucl Eng Des 2017; 324:111-21.

[49]

Sun J, Deng J, Ran X, Cao X, Fan G, Ding M. Experimental research on the mechanisms of condensation induced water hammer in a natural circulation system. Nucl Eng Technol 2021; 53(11):3635-42.

[50]

Sun J, Lu C, Mi Z, Cao X, Ding M. Experimental research on characteristics of condensation induced water hammer in natural circulation systems. Int Commun Heat Mass Transf 2020; 114:104559.

[51]

Hou X, Sun Z, Sun Q, Fan G, Lei W. Experimental study on geysering in an open natural circulation system. J Harbin Eng Univ 2016; 37(4):556-61. Chinese.

[52]

Hou X, Sun Z. Linear homogeneous-flow model of flashing instability in open natural circulation system. J Harbin Eng Univ 2016; 37(7):930-5. Chinese.

[53]

Hou X, Sun Z, Fan G, Lu W. Experimental investigation of startup characteristics in open natural circulation system. At Energy Sci Technol 2015; 49(10):1772-7.

[54]

Qi X, Zhao Z, Ai P, Chen P, Sun Z, Meng Z. Experiment investigation on flow characteristics of open natural circulation system. Nucl Eng Technol 2022; 54 (5):1851-9.

[55]

Yan X, Fan G, Sun Z. Study on flow characteristics in an open two-phase natural circulation loop. Ann Nucl Energy 2017; 104:291-300.

[56]

Hou X, Sun Z, Fan G, Wang L. Experimental and analytical investigation on the flow characteristics in an open natural circulation system. Appl Therm Eng 2017; 124:673-87.

[57]

Hou X, Sun Z, Su J, Fan G. An investigation on flashing instability induced water hammer in an open natural circulation system. Prog Nucl Energy 2016; 93:418-30.

[58]

Hou X, Sun Z, Lei W. Capability of RELAP5 code to simulate the thermal- hydraulic characteristics of open natural circulation. Ann Nucl Energy 2017; 109:612-25.

[59]

Li W, Du S, Gu W, Zhang N, Ding M, Sun Z, et al. An integrated experimental test facility to support development of the passive containment cooling system of HPR1000. In:Proceedings of 2020 International Conference on Nuclear Engineering; 2020 Apr 4-5; online. Nuclear Engineering Division; 2020.

[60]

Xing J, Liu Z, Ma W, Yuan Y, Sun Z, Li W, et al. Scaling analysis and evaluation for the design of integral test facility of HPR1000 containment (PANGU). Nucl Eng Des 2021; 373:111035.

AI Summary AI Mindmap
PDF (3910KB)

2803

Accesses

0

Citation

Detail