脉冲电晕等离子体烟气脱硫工业试验研究

赵君科、王保健、任先文、朱祖良

中国工程科学 ›› 2002, Vol. 4 ›› Issue (2) : 74-78.

PDF(2407 KB)
PDF(2407 KB)
中国工程科学 ›› 2002, Vol. 4 ›› Issue (2) : 74-78.
研究报告

脉冲电晕等离子体烟气脱硫工业试验研究

  • 赵君科、王保健、任先文、朱祖良

作者信息 +

SO2 Removal Experiment from Industrial-scale Flue Gas Using Pulsed Corona Process

  • Zhao Junke、 Wang Baojian、 Ren Xianwen、 Zhu Zuliang

Author information +
History +

摘要

利用建造在四川绵阳科学城热电厂的最大烟气处理量为20000 m3/h的脉冲电晕等离子体烟气脱硫工业中试装置,研究了影响脱硫效率的因素,获得了最佳工艺参数。究结果表明,当烟气温度在65~70℃,烟气水分含量约10%,氨硫化学剂量比为1∶1,烟停留时间大于6 s、能耗低于5 Wh/Nm3等条件下,脱硫率达85%以上。

Abstract

The paper gives the main parameters for S02 removal with gas flow rates of less than 2 × 104 Nm3/h by using pulsed corona process. This industrial-scale facility was constructed at the power plant of China's Science City in Mianyang,Sichuan Prorince. The results show that under such condition as:flue gas flow rate being less than 2 × 104 m3/h, gas temperature being 65~70℃,water content in the gas being 10%,resident time being 6~10 seconds, stoichiometric ratio of NH3 to SO2 being about1: 1, power consumption to operate the pulse conora process being not larger than 5 Wh/Nm3, the SO2 removal efficiency is about 85 % .

关键词

脉冲电晕放电 / 脱硫 / 工业中试

Keywords

pulsed corona discharge / SO2 removal / industrial-scale test

引用本文

导出引用
赵君科,王保健,任先文,朱祖良. 脉冲电晕等离子体烟气脱硫工业试验研究. 中国工程科学. 2002, 4(2): 74-78

参考文献

基金
“九五”国家重点科技攻关项目(96-910-02)
PDF(2407 KB)

Accesses

Citation

Detail

段落导航
相关文章

/