地下长通道补气口位置对火灾机械排烟效率的影响
胡隆华、霍然、李元洲、易亮、王浩波
Effect of Position of Air Supply Opening on the Efficiency of Smoke Extraction in an Underground Long Channel
Hu Longhua、 Huo Ran、 Li Yuanzhou、 Yi Liang、 Wang Haobo
在地下长通道内开展了针对一组相对位置不同的补气口—排烟口的排烟效果的全尺寸对比试验。结果表明,在地下长通道内设置的补气口—排烟口在针对发生火灾情况的优化组合上,应尽量遵循“远端补气、近端排烟”的原则。
A set of full scale contrast tests, with different relative positions of air supply opening and smoke exhaust opening, were conducted in an 88 m long underground corridor to study the effect of position of air supply opening on the efficiency of smoke extraction in a long channel. Results showed that the rule for designing the relative positions of air supply openings and smoke exhaust openings or operating them in a long channel should be “Smoke exhaust near the fire with air supply far away from the fire”.
地下长通道 / 补气口 / 排烟口 / 机械排烟效率 / 火灾
air supply position / smoke extraction efficiency / underground long channel / full scale test / fire
/
〈 |
|
〉 |