地铁火灾中强制通风烟控系统作用的模拟

蔡波1、李辉亮2、廖光煊1

中国工程科学 ›› 2005, Vol. 7 ›› Issue (8) : 80-83.

PDF(1966 KB)
PDF(1966 KB)
中国工程科学 ›› 2005, Vol. 7 ›› Issue (8) : 80-83.
研究报告

地铁火灾中强制通风烟控系统作用的模拟

  • 蔡波1、李辉亮2、廖光煊1

作者信息 +

Simulation of Effect of Forced Ventilated and Smoke Controlled System in Subway Fire Disaster

  • Cai Bo1、 Li Huiliang2、 Liao Guangxuan1

Author information +
History +

摘要

地铁火灾比地面火灾具有更大的危险性。通过对地铁火灾的模拟可以重现火灾过程,研究火灾现象,分析火灾原因。通过FDS模拟,对比大邱市地铁火灾在有无强制通风烟控系统条件下,火灾现场的温度场和烟尘分布,研究讨论其对控制地铁火灾的重要作用。

Abstract

Subway fire disaster is more hazardous than overground fire. Daegu underground railway fire disaster in Korea leads to a disastrous result. By means of fire simulation, recurrence of fire process, fire phenomenon and its reason could be studied. Based on FDS, the distribution of temperature and smoke with or without forced ventilated and smoke controlled system in Daegu subway fire are compared, and the effect on subway fire disaster control is also discussed in this paper.

关键词

地铁火灾 / FDS数值模拟 / 强制通风烟控系统

Keywords

subway fire disaster / FDS simulation / forced ventilated smoke controlled system

引用本文

导出引用
蔡波,李辉亮,廖光煊. 地铁火灾中强制通风烟控系统作用的模拟. 中国工程科学. 2005, 7(8): 80-83

参考文献

基金
国家自然科学基金重点专项基金资助项目(50323005)
PDF(1966 KB)

Accesses

Citation

Detail

段落导航
相关文章

/