摘要
以甲醇为工质,在不同进口温度、质量流率、热流密度和倾角下,对低高宽比矩形微通道中流动沸腾压降特性进行了研究,并分别采用均相模型和分相模型对通道压降进行了计算。通过对比实验结果与计算结果发现,均相模型中两相平均粘度的计算应当采用Dukler公式,用其他计算式时误差较大;利用LockhartMartinelli关系式进行的分相模型计算发现,现有C值计算公式,如Chisholm,Lee and Lee,Mishima及Qu and Mudawar等,都不能用于预测该实验中低高宽比微通道的两相压降。实验发现当通
Abstract
Pressure drops of flow boiling in a single microchannel having low aspect ratio were studied with effects of the inlet temperature,mass flux,heat flux and the inclined angle using methanol as working fluid. The present experimental data were compared with the predictions of the homogeneous flow model and separated flow model respectively. The comparison indicates that the homogeneous flow model cannot predict the twophase pressure drop well except using the twophase viscosity model of the Dukler correlation. With the existing correlations for parameter C in LockhartMartinelli correlation such as Chisholm,Lee and Lee,Mishima,Qu and Mudawar , separated flow model also failed to predict the twophase pressure drop in the microchannel of this study . The experimental data in this work show that the interaction between vapor phase and liquid phase is decreased with the increasing quality when the quality reach a certain value , accordingly there needs a correlation for C which decreased with the decreasing mass flux .A new correlation to predict the twophase flow pressure drop in microchannels was developed in the form of the LockhartMartinelli correlation .It includes the effect of the hydraulic diameter and the effect of mass flux on the twophase flow pressure drop in microchannels .The new correlation developed in this study predicted the experimental data within a mean absolute error of 16.9%.
关键词
压降特性 /
均相模型 /
分相模型 /
微通道 /
流动沸腾
Keywords
pressure drop characteristics /
homogeneous flow model /
separated flow model /
microchannel /
flow boiling
张炳雷,徐进良,肖泽军.
低高宽比矩形微通道中流动沸腾的压降特性. 中国工程科学. 2007, 9(12): 86-93
{{custom_sec.title}}
{{custom_sec.title}}
{{custom_sec.content}}
参考文献
基金
中国核动力研究设计院 空泡物理和自然循环重点实验室2005年基金资助项目(51482080105ZK7601)