用于16.7 MeV脉冲高能γ探测的散射吸收方法研究

谭新建1,2、欧阳晓平()2、王群书2

中国工程科学 ›› 2009, Vol. 11 ›› Issue (8) : 48-51.

PDF(769 KB)
PDF(769 KB)
中国工程科学 ›› 2009, Vol. 11 ›› Issue (8) : 48-51.

用于16.7 MeV脉冲高能γ探测的散射吸收方法研究

  • 谭新建1,2、欧阳晓平()2、王群书2

作者信息 +

cattering-absorbing method for the detection of 16.7 MeV high-energy pulsed gamma

  • Tan Xinjian1,2、Ouyang Xiaoping2、Wang Qunshu2

Author information +
History +

摘要

理论分析计算的基础上,提出了基于康普顿效应的散射吸收探测方法,该方法能实现高低能γ灵敏度比值达106~108,且对高能γ灵敏度较大,为10-21~10-16 C·cm2,其性能指标在一定程度上优于目前使用的基于磁分析器与Cherenkov探测器的高能γ探测方法指标。

Abstract

This paper proposes a new method of diagnosing 16.7 MeV high-energy pulsed gamma, named "scattering-absorbing method" . The ratio of the sensitivity of HEG to that of the LEG can reach 106 to 108 by this new method. The sensitivity of 16.7 MeV high-energy gamma ranges from 10-21 to 10-16 C·cm2. It's better than the traditional method which bases on the magnetic analyzer and Cherenkov detector on some aspects.

关键词

高能γ / 切伦柯夫探测器 / 散射吸收法

Keywords

high-energy gamma / Cherenkov detector / scattering absorption method

引用本文

导出引用
谭新建,欧阳晓平,王群书. 用于16.7 MeV脉冲高能γ探测的散射吸收方法研究. 中国工程科学. 2009, 11(8): 48-51

参考文献

PDF(769 KB)

Accesses

Citation

Detail

段落导航
相关文章

/