The burnup calculation for in-hospital neutron irradiator mark 1 reactor based on coupled code of WIMS and MCNP

Guo Hewei,Jiang Xinbiao,Zhao Zhumin,Chen Lixin,Zhang Xinyi,Zhou Yongmao

Strategic Study of CAE ›› 2012, Vol. 14 ›› Issue (8) : 64 -68.

PDF (1330KB)
Strategic Study of CAE ›› 2012, Vol. 14 ›› Issue (8) : 64 -68.

The burnup calculation for in-hospital neutron irradiator mark 1 reactor based on coupled code of WIMS and MCNP

Author information +
History +
PDF (1330KB)

Abstract

The paper set up the coupled calculation methods of criticality and burnup based on WIMS code and MCNP code, and validated the method. Through the calculation results of cells and the comparison of burnup experiments of Xi’an pulsed reactor, the validity and rationality of the coupled code were proved. The article utilized the coupled code to compute and analyze the burnup of in hospital neutron irradiator mark 1(IHNI-1) reactor at last.

Keywords

IHNI-1 reactor / coupled code / burnup

Cite this article

Download citation ▾
Guo Hewei,Jiang Xinbiao,Zhao Zhumin,Chen Lixin,Zhang Xinyi,Zhou Yongmao. The burnup calculation for in-hospital neutron irradiator mark 1 reactor based on coupled code of WIMS and MCNP. Strategic Study of CAE, 2012, 14(8): 64-68 DOI: