资源类型

期刊论文 3

年份

2021 1

2019 1

2009 1

关键词

检索范围:

排序: 展示方式:

Comparative study of oscillating flow characteristics of cryocooler regenerator at low temperatures

Yonglin JU , Qingqing SHEN ,

《能源前沿(英文)》 2009年 第3卷 第1期   页码 80-84 doi: 10.1007/s11708-009-0008-y

摘要: A brief review is presented on previous experimental results and correlations on the friction factor of cryocooler regenerators operating at oscillating flow and pulsating pressure conditions, for different mesh sizes of packed woven screens, focusing on the effects of different operating frequencies ranging from 20 to 80 Hz, at room and cryogenic temperatures. A comparison of the friction factor data with those of other studies is presented to clarify the reason for the difference. Finally, a new oscillating flow correlation of regenerators, in terms of several non-dimensional parameters, is discussed and compared.

关键词: friction factor     regenerator     oscillating flow     high frequency    

Performance improvement of a pulse tube cryocooler with a single compressor through cascade utilization

Xuming LIU, Xiafan XU, Biao YANG, Xiaotong XI, Liubiao CHEN, Junjie WANG, Yuan ZHOU

《能源前沿(英文)》 2021年 第15卷 第2期   页码 345-357 doi: 10.1007/s11708-020-0708-x

摘要: The high-frequency pulse tube cryocooler (HPTC) has been attracting increasing and widespread attention in the field of cryogenic technology because of its compact structure, low vibration, and reliable operation. The gas-coupled HPTC, driven by a single compressor, is currently the simplest and most compact structure. For HPTCs operating below 20 K, in order to obtain the mW cooling capacity, hundreds or even thousands of watts of electrical power are consumed, where radiation heat leakage accounts for a large proportion of their cooling capacity. In this paper, based on SAGE10, a HPTC heat radiation calculation model was first established to study the effects of radiation heat leakage on apparent performance parameters (such as temperature and cooling capacity), and internal parameters (such as enthalpy flow and gas distribution) of the gas-coupled HPTC. An active thermal insulation method of cascade utilization of the cold energy of the system was proposed for the gas-coupled HPTC. Numerical simulations indicate that the reduction of external radiation heat leakage cannot only directly increase the net cooling power, but also decrease the internal gross losses and increase the mass and acoustic power in the lower-temperature section, which further enhances the refrigeration performance. The numerical calculation results were verified by experiments, and the test results showed that the no-load temperature of the developed cryocooler prototype decreased from 15.1 K to 6.4 K, and the relative Carnot efficiency at 15.5 K increased from 0.029% to 0.996% when substituting the proposed active method for the traditional passive method with multi-layer thermal insulation materials.

关键词: radiation heat leakage     active thermal insulation     cascade utilization     cold energy     performance improvement     cryocooler    

and experimental verifications of the single-compressor-driven three-stage Stirling-type pulse tube cryocooler

Haizheng DANG, Dingli BAO, Zhiqian GAO, Tao ZHANG, Jun TAN, Rui ZHA, Jiaqi LI, Ning LI, Yongjiang ZHAO, Bangjian ZHAO

《能源前沿(英文)》 2019年 第13卷 第3期   页码 450-463 doi: 10.1007/s11708-018-0569-8

摘要: This paper establishes a theoretical model of the single-compressor-driven (SCD) three-stage Stirling-type pulse tube cryocooler (SPTC) and conducts experimental verifications. The main differences between the SCD type and the multi-compressor-driven (MCD) cryocooler are analyzed, such as the distribution of the input acoustic power in each stage and the optimization of the operating parameters, in which both advantages and difficulties of the former are stressed. The effects of the dynamic temperatures are considered to improve the accuracy of the simulation at very low temperatures, and a specific simulation example aiming at 10 K is given in which quantitative analyses are provided. A SCD three-stage SPTC is developed based on the theoretical analyses and with a total input acoustic power of 371.58 W, which reaches a no-load temperature of 8.82 K and can simultaneously achieve the cooling capacities of 2.4 W at 70 K, 0.17 W at 25 K, and 0.05 W at 10 K. The performance of the SCD three-stage SPTC is slightly poorer than that of its MCD counterpart developed in the same laboratory, but the advantages of lightweight and compactness make the former more attractive to practical applications.

关键词: single-compressor-driven     three-stage     Stirling-type pulse tube cryocooler     theoretical modeling     experimental verification    

标题 作者 时间 类型 操作

Comparative study of oscillating flow characteristics of cryocooler regenerator at low temperatures

Yonglin JU , Qingqing SHEN ,

期刊论文

Performance improvement of a pulse tube cryocooler with a single compressor through cascade utilization

Xuming LIU, Xiafan XU, Biao YANG, Xiaotong XI, Liubiao CHEN, Junjie WANG, Yuan ZHOU

期刊论文

and experimental verifications of the single-compressor-driven three-stage Stirling-type pulse tube cryocooler

Haizheng DANG, Dingli BAO, Zhiqian GAO, Tao ZHANG, Jun TAN, Rui ZHA, Jiaqi LI, Ning LI, Yongjiang ZHAO, Bangjian ZHAO

期刊论文