资源类型

期刊论文 38

年份

2023 4

2022 6

2021 3

2020 2

2019 5

2018 4

2017 3

2016 2

2015 1

2014 2

2013 1

2010 3

2007 2

展开 ︾

关键词

膜污染 2

超滤 2

GDM过滤技术 1

两亲高分子 1

乳液 1

亲水 1

亲水性 1

共混微孔膜 1

分子间力和表面力 1

化学强化反冲洗(CEB) 1

反渗透膜 1

含有藻类的地表水 1

影响因素 1

抗污染 1

改性方法 1

水力不可逆的膜污染 1

水处理 1

生物膜 1

界面 1

展开 ︾

检索范围:

排序: 展示方式:

Ceramic membrane fouling mechanisms and control for water treatment

《环境科学与工程前沿(英文)》 2023年 第17卷 第10期 doi: 10.1007/s11783-023-1726-9

摘要:

● The fouling is summarized based on ceramic membrane performance and pollutants.

关键词: Ceramic membrane     Fouling model     Fouling control    

Characterization of electrode fouling during electrochemical oxidation of phenolic pollutant

Xuefeng Liu, Shijie You, Fang Ma, Hao Zhou

《环境科学与工程前沿(英文)》 2021年 第15卷 第4期 doi: 10.1007/s11783-020-1345-7

摘要: Abstract • Electrode fouling is characterized by non-destructive characterization. • Electrode fouling is highly dependent on electrochemical process. • Active chlorine can prevent the formation of polymeric fouling film. Electrode fouling is a problem that commonly occurs during electro-oxidation water purification. This study focused on identifying the fouling behavior of Pt electrode associated with the formation of polymeric layer during electro-oxidation of phenol. The in situ electrochemical measurements and non-destructive observation of the electrode morphology were reported. The results demonstrated that the electrode fouling was highly dependent on thermodynamic process of electrode that was controlled by anode potential. At anode potential lower than 1.0 V vs SHE, the direct electro-oxidation caused the electrode fouling by the formation of polymeric film. The fouling layer decreased the electrochemically active surface area from 8.38 cm2 to 1.57 cm2, indicated by the formation of polymeric film with thickness of 2.3 mm, increase in mass growing at a rate of 3.26 μg/cm2/min. The degree to which the anode was fouled was independent of anion in the electrolyte. In comparison, at anode potential higher than 2.7 V vs SHE, the anions (e.g., chloride) could exert a major influence to the behavior of electrode fouling. The presence of chloride was shown to mitigate the fouling of electrode significantly through preventing the formation of polymeric film by active chlorine (e.g., Cl• and Cl2) produced from anodic oxidation of chloride. Since chloride is the most abundant anionic species existing in both natural and engineered water system, this study not only offers a deep insight into the mechanism of electrode fouling, but also suggests strategies for anti-fouling in the presence of chloride in electro-oxidation process.

关键词: Electro-oxidation     Electrode fouling     Polymeric film     Chloride ions    

A review on the forward osmosis applications and fouling control strategies for wastewater treatment

《化学科学与工程前沿(英文)》 2022年 第16卷 第5期   页码 661-680 doi: 10.1007/s11705-021-2084-4

摘要: During the last decades, the utilization of osmotic pressure-driven forward osmosis technology for wastewater treatment has drawn great interest, due to its high separation efficiency, low membrane fouling propensity, high water recovery and relatively low energy consumption. This review paper summarizes the implementation of forward osmosis technology for various wastewater treatment including municipal sewage, landfill leachate, oil/gas exploitation wastewater, textile wastewater, mine wastewater, and radioactive wastewater. However, membrane fouling is still a critical issue, which affects water flux stability, membrane life and operating cost. Different membrane fouling types and corresponding fouling mechanisms, including organic fouling, inorganic fouling, biofouling and combined fouling are therefore further discussed. The fouling control strategies including feed pre-treatment, operation condition optimization, membrane selection and modification, membrane cleaning and tailoring the chemistry of draw solution are also reviewed comprehensively. At the end of paper, some recommendations are proposed.

关键词: forward osmosis     wastewater treatment     membrane fouling     fouling control    

A critical review on thermodynamic mechanisms of membrane fouling in membrane-based water treatment process

《环境科学与工程前沿(英文)》 2023年 第17卷 第10期 doi: 10.1007/s11783-023-1729-6

摘要:

● Fundamentals of membrane fouling are comprehensively reviewed.

关键词: Membrane fouling     Thermodynamic mechanism     XDLVO theory     Flory-Huggins theory     Fouling migration    

Membrane fouling control by ultrasound in an anaerobic membrane bioreactor

SUI Pengzhe, WEN Xianghua, HUANG Xia

《环境科学与工程前沿(英文)》 2007年 第1卷 第3期   页码 362-367 doi: 10.1007/s11783-007-0062-9

摘要: In this study, ultrasound was used to control the membrane fouling online in an anaerobic membrane bioreactor (AMBR). Short-term running experiments were carried out under different operating conditions to explore feasible ultrasonic parameters. The experimental results indicated that when the crossflow velocity was more than 1.0 m/s, membrane fouling could be controlled effectively only by hydrodynamic methods without ultrasound. When ultrasound was applied, an ultrasonic power range of 60–150 W was suitable for the membrane fouling control in the experimental system. The experimental results showed that the membrane fouling was controlled so well that membrane filtration resistance (Σ) could stay at 5 × 10 m for more than a week with the crossflow velocity of 0.75 m/s, which equaled the effect of crossflow velocity of more than 1.0 m/s without ultrasound.

关键词: membrane filtration     filtration resistance     different     feasible ultrasonic     anaerobic membrane    

On the fouling mechanism of polysulfone ultrafiltration membrane in the treatment of coal gasification

Xue Zou,Jin Li

《化学科学与工程前沿(英文)》 2016年 第10卷 第4期   页码 490-498 doi: 10.1007/s11705-016-1600-4

摘要: Membrane fouling has been investigated by using a polysulfone ultrafiltration membrane with the molecular weight cutoff of 20 kDa to treat crushed coal pressurized gasification wastewater. Under the conditions of different feed pressures, the permeate flux declines and rejection coefficients of pollutants referring to three parameters (total organic carbon (TOC), chroma and turbidity) were studied. The membrane fouling mechanism was simulated with three classical membrane fouling models. The membrane image and pollutants were analyzed by scanning electron microscopy and gas chromatography-mass spectrography (GC-MS). The results indicate that the permeate flux decreases with volume reduction factor before reaching a constant value. The rejection coefficients were also measured: = 70.5%, = 84.9% and = 91%. Further analysis shows that the higher the feed pressure is, the sooner the permeate flux reaches constant value and the more sharply the permeate flux declines. Constant flux indicates a nonlinear growth with feed pressure ( ): when equals 1.2 bar, the mark for the critical flux, slight membrane fouling occurs; when exceeds 1.2 bar, cake layer pollution aggravates. Also the rejection coefficients of global pollutant increases slightly with , suggesting the possibility of cake compression when exceeds 1.2 bar. Through regression analysis, the fouling of polysulfone ultrafiltration membrane could be fitted very well by cake filtration model. The membrane pollutants were identified as phthalate esters and long-chain alkenes by GC-MS, and a certain amount of inorganic pollutants by X-ray photoelectron spectroscopy.

关键词: membrane fouling     ultrafiltration membrane     coal gasification wastewater     rejection coefficient    

Effect of chemical dose on phosphorus removal and membrane fouling control in a UCT-MBR

Guangrong Sun, Chuanyi Zhang, Wei Li, Limei Yuan, Shilong He, Liping Wang

《环境科学与工程前沿(英文)》 2019年 第13卷 第1期 doi: 10.1007/s11783-019-1085-8

摘要: To enhance phosphorus removal and make the effluent meet the strict discharge level of total phosphorus (TP, 0.5 mg/L), flocculant dosing is frequently applied. In this study, the performance of aluminum sulfate dosing in a University of Cape Town Membrane Bioreactor (UCT-MBR) was investigated, in terms of the nutrients removal performance, sludge characteristics and membrane fouling. The results indicated that the addition of aluminum sulfate into the aerobic reactor continuously had significantly enhanced phosphorus removal. Moreover, COD, NH -N and TN removal were not affected and effluent all met the first level A criteria of GB18918-2002. In addition, the addition of aluminum sulfate had improved the sludge activity slightly and reduced trans-membrane pressure (TMP) increase rate from 1.13 KPa/d to 0.57 KPa/d effectively. The membrane fouling was alleviated attributed to the increased average particle sizes and the decreased accumulation of the small sludge particles on membrane surface. Furthermore, the decline of extracellular polymeric substance (EPS) concentration in mixed sludge liquid decreased its accumulation on membrane surface, resulting in the mitigation of membrane fouling directly.

关键词: University of Cape Town Bioreactor (UCT-MBR)     enhanced nutrients removal     aluminum sulfate     sludge activity     membrane fouling    

Effect of protein on PVDF ultrafiltration membrane fouling behavior under different pH conditions: interface

Xudong WANG,Miao ZHOU,Xiaorong MENG,Lei WANG,Danxi HUANG

《环境科学与工程前沿(英文)》 2016年 第10卷 第4期 doi: 10.1007/s11783-016-0855-9

摘要: pH values of the BSA solution significantly impact the process of membrane fouling. Dramatic flux decline is caused by membrane–BSA adhesion force at start of filtration. XDLVO theory shows the polar or Lewis acid–base interaction plays a major role in membrane fouling. To further determine the fouling behavior of bovine serum albumin (BSA) on different hydrophilic PVDF ultrafiltration (UF) membranes over a range of pH values, self-made atomic force microscopy (AFM) colloidal probes were used to detect the adhesion forces of membrane–BSA and BSA–BSA, respectively. Results showed that the membrane–BSA adhesion interaction was stronger than the BSA–BSA adhesion interaction, and the adhesion force between BSA–BSA-fouled PVDF/PVA membranes was similar to that between BSA–BSA-fouled PVDF/PVP membranes, which indicated that the fouling was mainly caused by the adhesion interaction between membrane and BSA. At the same pH condition, the PVDF/PVA membrane–BSA adhesion force was smaller than that of PVDF/PVP membrane–BSA, which illustrated that the more hydrophilic the membrane was, the better antifouling ability it had. The extended Derjaguin–Landau–Verwey–Overbeek (XDLVO) theory predicts that the polar or Lewis acid–base (AB) interaction played a dominant role in the interfacial free energy of membrane–BSA and BSA–BSA that can be affected by pH. For the same membrane, the pH values of a BSA solution can have a significant impact on the process of membrane fouling by changing the AB component of free energy.

关键词: PVDF membrane     Membrane fouling     Adhesion force     Protein     Interfacial free energy    

Design of nanofibre interlayer supported forward osmosis composite membranes and its evaluation in fouling

《环境科学与工程前沿(英文)》 2022年 第16卷 第9期 doi: 10.1007/s11783-022-1550-7

摘要:

• A fine fibre (40–60 nm diameter) interlayer (~1 µm thickness) was electrospun.

关键词: Forward osmosis     Electro-spinning     Interfacial polymerisation     Fouling     Polyvinylidene fluoride    

cross-flow filtration with flat-sheet ceramic membranes by titanium-based coagulation for membrane fouling

《环境科学与工程前沿(英文)》 2022年 第16卷 第8期 doi: 10.1007/s11783-022-1531-x

摘要:

• Ceramic membrane filtration showed high performance for surface water treatment.

关键词: Ceramic membrane     Coagulation     Polytitanium chloride     Membrane fouling    

Evolution of composite fouling on a vertical stainless steel surface caused by treated sewage

Cheng ZAN, Lin SHI, Xiujuan MA, Wenyan YANG,

《能源前沿(英文)》 2010年 第4卷 第2期   页码 171-180 doi: 10.1007/s11708-009-0068-z

摘要: Composite biological and inorganic fouling occurs in plate heat exchangers (PHEs) using treated sewage as heat transfer medium, which lowers the heat transfer coefficient and increases the frictional resistance. In order to optimize the heat exchange process and improve the anti-fouling strategies, the dynamic behavior of composite fouling at a vertical surface of stainless steel (ANSI 316L) was investigated under typical conditions of PHEs. The growth curves of composite fouling were obtained. The evolution of composite fouling was characterized by means of environmental scanning electron microscopy (ESEM). Backscattered Electron Image (BEI) and energy dispersive X-ray spectrometry (EDS) were used as aids in interpreting the results. The experimental results show that a preliminary stage of a 6-day period with a low fouling growth rate exists during the composite fouling development. A significant change of the fouling growth rate happens after the preliminary stage during which the bacterial behaviors at the surface could be recorded clearly. After the preliminary stage, a space net-shape, mainly consisting of bacteria, extracellular products (EPS) and inorganic particles, could be established on the surface of the fouling layer. The change of fouling growth rate occurs synchronously with the evolution.

关键词: treated sewage     plate heat exchanger     stainless steel     composite fouling     biofouling    

Accounting for local features of fouling formation on PHE heat transfer surface

Petro Kapustenko, Jiří J. Klemeš, Olga Arsenyeva, Olexandr Matsegora, Oleksandr Vasilenko

《化学科学与工程前沿(英文)》 2018年 第12卷 第4期   页码 619-629 doi: 10.1007/s11705-018-1736-5

摘要: The fouling phenomena can create significant operational problems in the industry by deteriorating heat recuperation, especially in heat exchangers with enhanced heat transfer. For a correct prediction of fouling development, the reliable fouling models must be used. The analysis of existing fouling models is presented. The chemical reaction and transport model developed earlier for a description of fouling on intensified heat transfer surfaces is used for modeling of plate heat exchanger (PHE) subjected to fouling. The mathematical model consists of a system of differential and algebraic equations. The integration of it is performed by finite difference method with developed software for personal computer. For countercurrent streams arrangement in PHE the solution of two-point boundary problem is realized on every time step. It enables to estimate local parameters of heat transfer process with fouling formation and its development in time with the growth of deposited fouling layer. Two examples of model application in cases of PHEs working at sugar factory and in district heating network are presented. The comparison with experimental data confirmed the model validity and the possibility of its application to determine the performance of PHE subjected to fouling.

关键词: heat transfer     fouling     plate heat exchanger     mathematical model    

Relationship between sludge settleability and membrane fouling in a membrane bioreactor

SUN Yujiao, WANG Yong, HUANG Xia

《环境科学与工程前沿(英文)》 2007年 第1卷 第2期   页码 221-225 doi: 10.1007/s11783-007-0038-9

摘要: The evolution of activated sludge settleability and its relationship to membrane fouling in a submerged membrane bioreactor were studied at a lab-scale equipment fed with synthetic wastewater. It was found that sludge volume index (SVI) gradually increased and the sludge settleability was reduced, which was caused by the propagation of filamentous bacteria. With increasing SVI, the average increasing rate of trans-membrane pressure increased, the stable filtration period was shortened, and the two stages (smooth stage and accelerating stage) of the trans-membrane pressure were more obvious. At the same time, the increasing rate of trans-membrane pressure at the smooth stage decreased and the rate at the accelerating stage increased with SVI, respectively. The observation by using scanning electronic microscopes showed the cake layer with loose structure and large thickness formed on the membrane surface due to the appearance of filamentous bacteria and high SVI in sludge. Influence of the sludge settleability on the trans-membrane pressure was related to the structure and thickness of the cake layer on the membrane.

关键词: Influence     bioreactor     activated     filamentous     lab-scale equipment    

Metabolic uncoupler, 3,3′,4′,5-tetrachlorosalicylanilide addition for sludge reduction and fouling control

An Ding, Yingxue Zhao, Huu Hao Ngo, Langming Bai, Guibai Li, Heng Liang, Nanqi Ren, Jun Nan

《环境科学与工程前沿(英文)》 2020年 第14卷 第6期 doi: 10.1007/s11783-020-1275-4

摘要: Abstract • Effects of metabolic uncoupler TCS on the performances of GDMBR were evaluated. • Sludge EPS reduced and transformed into dissolved SMP when TCS was added. • Appropriate TCS increased the permeability and reduced cake layer fouling. • High dosage aggravated fouling due to compact cake layer with low bio-activity. The gravity-driven membrane bioreactor (MBR)system is promising for decentralized sewage treatment because of its low energy consumption and maintenance requirements. However, the growing sludge not only increases membrane fouling, but also augments operational complexities (sludge discharge). We added the metabolic uncoupler 3,3′,4′,5-tetrachlorosalicylanilide (TCS) to the system to deal with the mentioned issues. Based on the results, TCS addition effectively decreased sludge ATP and sludge yield (reduced by 50%). Extracellular polymeric substances (EPS; proteins and polysaccharides) decreased with the addition of TCS and were transformed into dissolved soluble microbial products (SMPs) in the bulk solution, leading to the break of sludge flocs into small fragments. Permeability was increased by more than two times, reaching 60–70 L/m2/h bar when 10–30 mg/L TCS were added, because of the reduced suspended sludge and the formation of a thin cake layer with low EPS levels. Resistance analyses confirmed that appropriate dosages of TCS primarily decreased the cake layer and hydraulically reversible resistances. Permeability decreased at high dosage (50 mg/L) due to the release of excess sludge fragments and SMP into the supernatant, with a thin but more compact fouling layer with low bioactivity developing on the membrane surface, causing higher cake layer and pore blocking resistances. Our study provides a fundamental understanding of how a metabolic uncoupler affects the sludge and bio-fouling layers at different dosages, with practical relevance for in situ sludge reduction and membrane fouling alleviation in MBR systems.

关键词: Gravity-driven membrane (GDM)     Energy uncoupling     Permeability     Sludge reduction     Membrane fouling     Fouling layer    

ultrafiltration in sludge treatment: Evaluations of sludge reduction, supernatant recovery and membrane fouling

An Ding, Yingxue Zhao, Zhongsen Yan, Langming Bai, Haiyang Yang, Heng Liang, Guibai Li, Nanqi Ren

《环境科学与工程前沿(英文)》 2020年 第14卷 第4期 doi: 10.1007/s11783-020-1238-9

摘要: Effects of metabolic uncouplers addition on sludge reduction were carried out. TCS addition effectively inhibited ATP synthesis and reduced sludge yield. The effluent quality such as TOC and ammonia deteriorated but not significantly. Suitable dosage retarded biofouling during sludge water recovery by UF membrane. Energy uncoupling is often used for sludge reduction because it is easy to operate and does not require a significant amount of extra equipments (i.e. no additional tank required). However, over time the supernatant extracted using this method can deteriorate, ultimately requiring further treatment. The purpose of this study was to determine the effect of using a low-pressure ultrafiltration membrane process for sludge water recovery after the sludge had undergone an energy uncoupling treatment (using 3,3′,4′,5-tetrachlorosalicylanilide (TCS)). Energy uncoupling was found to break apart sludge floc by reducing extracellular polymeric substances (EPS) and adenosine triphosphate (ATP) content. Analysis of supernatant indicated that when energy uncoupling and membrane filtration were co-applied and the TCS dosage was below 30 mg/L, there was no significant deterioration in organic component removal. However, ammonia and phosphate concentrations were found to increase as the concentration of TCS added increased. Additionally, due to low sludge concentrations and EPS contents, addition of 30–60 mg/L TCS during sludge reduction increased the permeate flux (two times higher than the control) and decreased the hydraulic reversible and cake layer resistances. In contrast, high dosage of TCS aggravated membrane fouling by forming compact fouling layers. In general, this study found that the co-application of energy uncoupling and membrane filtration processes represents an effective alternative method for simultaneous sludge reduction and sludge supernatant recovery.

关键词: Sludge reduction     Energy uncoupling     Ultrafiltration membrane     Membrane fouling    

标题 作者 时间 类型 操作

Ceramic membrane fouling mechanisms and control for water treatment

期刊论文

Characterization of electrode fouling during electrochemical oxidation of phenolic pollutant

Xuefeng Liu, Shijie You, Fang Ma, Hao Zhou

期刊论文

A review on the forward osmosis applications and fouling control strategies for wastewater treatment

期刊论文

A critical review on thermodynamic mechanisms of membrane fouling in membrane-based water treatment process

期刊论文

Membrane fouling control by ultrasound in an anaerobic membrane bioreactor

SUI Pengzhe, WEN Xianghua, HUANG Xia

期刊论文

On the fouling mechanism of polysulfone ultrafiltration membrane in the treatment of coal gasification

Xue Zou,Jin Li

期刊论文

Effect of chemical dose on phosphorus removal and membrane fouling control in a UCT-MBR

Guangrong Sun, Chuanyi Zhang, Wei Li, Limei Yuan, Shilong He, Liping Wang

期刊论文

Effect of protein on PVDF ultrafiltration membrane fouling behavior under different pH conditions: interface

Xudong WANG,Miao ZHOU,Xiaorong MENG,Lei WANG,Danxi HUANG

期刊论文

Design of nanofibre interlayer supported forward osmosis composite membranes and its evaluation in fouling

期刊论文

cross-flow filtration with flat-sheet ceramic membranes by titanium-based coagulation for membrane fouling

期刊论文

Evolution of composite fouling on a vertical stainless steel surface caused by treated sewage

Cheng ZAN, Lin SHI, Xiujuan MA, Wenyan YANG,

期刊论文

Accounting for local features of fouling formation on PHE heat transfer surface

Petro Kapustenko, Jiří J. Klemeš, Olga Arsenyeva, Olexandr Matsegora, Oleksandr Vasilenko

期刊论文

Relationship between sludge settleability and membrane fouling in a membrane bioreactor

SUN Yujiao, WANG Yong, HUANG Xia

期刊论文

Metabolic uncoupler, 3,3′,4′,5-tetrachlorosalicylanilide addition for sludge reduction and fouling control

An Ding, Yingxue Zhao, Huu Hao Ngo, Langming Bai, Guibai Li, Heng Liang, Nanqi Ren, Jun Nan

期刊论文

ultrafiltration in sludge treatment: Evaluations of sludge reduction, supernatant recovery and membrane fouling

An Ding, Yingxue Zhao, Zhongsen Yan, Langming Bai, Haiyang Yang, Heng Liang, Guibai Li, Nanqi Ren

期刊论文