SO2 Removal Experiment from Industrial-scale Flue Gas Using Pulsed Corona Process
Zhao Junke、 Wang Baojian、 Ren Xianwen、 Zhu Zuliang
Strategic Study of CAE ›› 2002, Vol. 4 ›› Issue (2) : 74-78.
SO2 Removal Experiment from Industrial-scale Flue Gas Using Pulsed Corona Process
Zhao Junke、 Wang Baojian、 Ren Xianwen、 Zhu Zuliang
The paper gives the main parameters for S02 removal with gas flow rates of less than 2 × 104 Nm3/h by using pulsed corona process. This industrial-scale facility was constructed at the power plant of China's Science City in Mianyang,Sichuan Prorince. The results show that under such condition as:flue gas flow rate being less than 2 × 104 m3/h, gas temperature being 65~70℃,water content in the gas being 10%,resident time being 6~10 seconds, stoichiometric ratio of NH3 to SO2 being about1: 1, power consumption to operate the pulse conora process being not larger than 5 Wh/Nm3, the SO2 removal efficiency is about 85 % .
pulsed corona discharge / SO2 removal / industrial-scale test
/
〈 |
|
〉 |