SO2 Removal Experiment from Industrial-scale Flue Gas Using Pulsed Corona Process

Zhao Junke、 Wang Baojian、 Ren Xianwen、 Zhu Zuliang

Strategic Study of CAE ›› 2002, Vol. 4 ›› Issue (2) : 74-78.

PDF(2407 KB)
PDF(2407 KB)
Strategic Study of CAE ›› 2002, Vol. 4 ›› Issue (2) : 74-78.
Research Report

SO2 Removal Experiment from Industrial-scale Flue Gas Using Pulsed Corona Process

  • Zhao Junke、 Wang Baojian、 Ren Xianwen、 Zhu Zuliang

Author information +
History +

Abstract

The paper gives the main parameters for S02 removal with gas flow rates of less than 2 × 104 Nm3/h by using pulsed corona process. This industrial-scale facility was constructed at the power plant of China's Science City in Mianyang,Sichuan Prorince. The results show that under such condition as:flue gas flow rate being less than 2 × 104 m3/h, gas temperature being 65~70℃,water content in the gas being 10%,resident time being 6~10 seconds, stoichiometric ratio of NH3 to SO2 being about1: 1, power consumption to operate the pulse conora process being not larger than 5 Wh/Nm3, the SO2 removal efficiency is about 85 % .

Keywords

pulsed corona discharge / SO2 removal / industrial-scale test

Cite this article

Download citation ▾
Zhao Junke,Wang Baojian,Ren Xianwen,Zhu Zuliang. SO2 Removal Experiment from Industrial-scale Flue Gas Using Pulsed Corona Process. Strategic Study of CAE, 2002, 4(2): 74‒78