Demolition Technique of High Thin-wall Hyperbolic Reinforced Concrete Cool Tower by Directional Controlled Blasting

Luo Yong

Strategic Study of CAE ›› 2008, Vol. 10 ›› Issue (4) : 40-45.

PDF(262 KB)
PDF(262 KB)
Strategic Study of CAE ›› 2008, Vol. 10 ›› Issue (4) : 40-45.

Demolition Technique of High Thin-wall Hyperbolic Reinforced Concrete Cool Tower by Directional Controlled Blasting

  • Luo Yong
Author information +
History +

Abstract

Based on blasting demolition of high thin-wall hyperbolic reinforced concrete cool tower, by virtue of engineering practice of blasting the tube concrete structures, the analysis and research were made on the mechanism of cool tower collapse through selecting blasting parameters and selecting gap form, gap size and gap angle. The cool tower was twisted, collapsed directionally and broken well according to the design requirements. The expected results and purposes of blasting were obtained with no back-blow, total blasted pile approximates to 4~5m height, no occurrence of flying stones and no damage to fixed buildings and equipments, the large-sized hyperbolic thin-wall reinforced concrete cool towers are twisted during blasting and it collapses well with good breaking. The test and measurement of blasting vibrating velocity was carried out during blasting and the measuring results are much less than critical values specified by safety regulations for blasting. The study shows that gap form, gap size and gap angle are the key factors to cool tower collapse and will give beneficial references to related theoretical study and field application.

Keywords

cool tower / blasting demolition / directional blasting / gap

Cite this article

Download citation ▾
Luo Yong. Demolition Technique of High Thin-wall Hyperbolic Reinforced Concrete Cool Tower by Directional Controlled Blasting. Strategic Study of CAE, 2008, 10(4): 40‒45
AI Summary AI Mindmap
PDF(262 KB)

Accesses

Citations

Detail

Sections
Recommended

/