The physics scheme design for In-Hospital Neutron Irradiator Mark 1 reactor loaded low enrichment fuel
Jiang Xinbiao1、Zhang Wenshou1、Gao Jijin2、Li Yiguo2、Zhou Yongmao3
Strategic Study of CAE ›› 2009, Vol. 11 ›› Issue (11) : 17-21.
The physics scheme design for In-Hospital Neutron Irradiator Mark 1 reactor loaded low enrichment fuel
Jiang Xinbiao1、Zhang Wenshou1、Gao Jijin2、Li Yiguo2、Zhou Yongmao3
The core physics properties of 30 kW In-Hospital Neutron Irradiator-Mark 1(IHNI-1) reactor loaded low-enrichment fuel are simulated by using MCNP/4B Monte Carlo code. The arrangement scheme of core, 235U enrichment, control rods' value, excess reactivity and shutdown margin are also reasonably introduced. The results show that the physics scheme of IHNI-1 reactor which possesses some particular characteristics, such as high inherent safety, 10 years lifetime without any refueling and low-enrichment UO2 fuel, has been discovered in the paper and it will provide theoretic basis for reactor engineering design and neutron beam design for Boron Neutron Capture Therapy in the future.
IHNI-1 reactor / boron neutron capture therapy / reactivity
/
〈 |
|
〉 |