Test operation of in-hospital neutron irradiator
Li Yiguo1,2、Peng Dan1、Zou Shuyun1、Wu Xiaobo1、Zhang Jinhua1、Zhang Zizhu1、Xia Pu1、Zou Xiaoyan2、Liu Tong2、Zhou Yongmao3
Strategic Study of CAE ›› 2012, Vol. 14 ›› Issue (8) : 23-27.
Test operation of in-hospital neutron irradiator
Li Yiguo1,2、Peng Dan1、Zou Shuyun1、Wu Xiaobo1、Zhang Jinhua1、Zhang Zizhu1、Xia Pu1、Zou Xiaoyan2、Liu Tong2、Zhou Yongmao3
In 2010, the commissioning of in-hospital neutron irradiator (IHNI) and its systems were completed. The operation with power started since then. The IHNI has operated by 99 times. The release of total energy is 1 832.42 kW·h with the corresponding integral neutron flux of 2.198 9×1017 cm-2. The test operation data shows that the operation values of IHNI and its relevant systems are smaller than the limited value, which manifests that IHNI is safe and reliable.
in-hospital neutron irradiator (IHNI) / test operation / limited value and condition
/
〈 |
|
〉 |