Numerical calculation for the equivalent surface source of the thermal neutron duct of in-hospital neutron irradiator mark 1 reactor

Zhu Yangni1、Jiang Xinbiao1、Zhao Zhumin1、Zhang Liang1、Zhou Yongmao2

Strategic Study of CAE ›› 2012, Vol. 14 ›› Issue (8) : 56-59.

PDF(1044 KB)
PDF(1044 KB)
Strategic Study of CAE ›› 2012, Vol. 14 ›› Issue (8) : 56-59.

Numerical calculation for the equivalent surface source of the thermal neutron duct of in-hospital neutron irradiator mark 1 reactor

  • Zhu Yangni1、Jiang Xinbiao1、Zhao Zhumin1、Zhang Liang1、Zhou Yongmao2

Author information +
History +

Abstract

Numerical calculation for the equivalent surface source of the thermal neutron duct of in-hospital neutron irradiator mark 1(IHNI-1) reactor is carried out using MCNP Monte Carlo code. Cold clean criticality of B core is searched. Neutron beam parameters at the exit of thermal neutron duct are calculated. Equivalent neutron and γ surface sources for BNCT are built using equivalent surface source model. And these sources are reliable to calculate absorbed dose distribution in equivalent model of head quickly.

Keywords

IHNI-1 reactor / thermal neutron duct / equivalent neutron surface source / equivalent γ surface source

Cite this article

Download citation ▾
Zhu Yangni,Jiang Xinbiao,Zhao Zhumin,Zhang Liang,Zhou Yongmao. Numerical calculation for the equivalent surface source of the thermal neutron duct of in-hospital neutron irradiator mark 1 reactor. Strategic Study of CAE, 2012, 14(8): 56‒59
AI Summary AI Mindmap