Numerical calculation for the equivalent surface source of the thermal neutron duct of in-hospital neutron irradiator mark 1 reactor
Zhu Yangni1、Jiang Xinbiao1、Zhao Zhumin1、Zhang Liang1、Zhou Yongmao2
Strategic Study of CAE ›› 2012, Vol. 14 ›› Issue (8) : 56-59.
Numerical calculation for the equivalent surface source of the thermal neutron duct of in-hospital neutron irradiator mark 1 reactor
Zhu Yangni1、Jiang Xinbiao1、Zhao Zhumin1、Zhang Liang1、Zhou Yongmao2
Numerical calculation for the equivalent surface source of the thermal neutron duct of in-hospital neutron irradiator mark 1(IHNI-1) reactor is carried out using MCNP Monte Carlo code. Cold clean criticality of B core is searched. Neutron beam parameters at the exit of thermal neutron duct are calculated. Equivalent neutron and γ surface sources for BNCT are built using equivalent surface source model. And these sources are reliable to calculate absorbed dose distribution in equivalent model of head quickly.
IHNI-1 reactor / thermal neutron duct / equivalent neutron surface source / equivalent γ surface source
/
〈 |
|
〉 |