Study on the performance of EDI device in dealing with Ni2 solution with dilute departments filled with cation exchange resins

Niu Yubiao、Xu Xiaoqing、Zhao Haiyang、Zhou Zhijun

Strategic Study of CAE ›› 2014, Vol. 16 ›› Issue (7) : 62-67.

PDF(2046 KB)
PDF(2046 KB)
Strategic Study of CAE ›› 2014, Vol. 16 ›› Issue (7) : 62-67.

Study on the performance of EDI device in dealing with Ni2 solution with dilute departments filled with cation exchange resins

  • Niu Yubiao、Xu Xiaoqing、Zhao Haiyang、Zhou Zhijun

Author information +
History +

Abstract

Study on the feasibility of EDI device, whose dilute departments were filled with cation exchange resins and feed water was low concentration Ni2 solution, for the treatment of low-concentration heavy-metal wastewater. The effects of operating voltage and dilute flow flux on the separation performances EDI processes were investigated. With the feed solution whose Ni2+ concentration was 50 mg·L-1 and pH was 4.5, the results show that the out dilute Ni2+concentration was lower than 2 mg·L-1 and the Ni2+ concentration of out concentrate could higher than 900 mg·L-1 when operating voltage was 25 v and dilute flow flux was 20 L·h-1.

Keywords

Electrodeionization (EDI) / cation exchange resin / heavy-metal / Ni2

Cite this article

Download citation ▾
Niu Yubiao,Xu Xiaoqing,Zhao Haiyang,Zhou Zhijun. Study on the performance of EDI device in dealing with Ni2 solution with dilute departments filled with cation exchange resins. Strategic Study of CAE, 2014, 16(7): 62‒67