资源类型

期刊论文 5

年份

2021 1

2015 2

2014 1

2007 1

关键词

8英寸 1

沟槽栅 1

绝缘栅双极型晶体管 (IGBT) 1

轨道交通 1

高功率密度 1

展开 ︾

检索范围:

排序: 展示方式:

Novel methods by using non-vacuum insulated tubing to extend the lifetime of the tubing

Chenglong ZHOU,Guojin ZHU,Yongxiang XU,Jifei YU,Xiaoliang ZHANG,Hongzhi SHENG

《能源前沿(英文)》 2015年 第9卷 第2期   页码 142-147 doi: 10.1007/s11708-015-0357-7

摘要: The analysis of the failure mechanics, namely hydrogen permeation of vacuum insulated tubing (VIT), indicated that the failure of VIT could be decreased but could not be avoided. To solve this problem, some measures by using non-vacuum materials were proposed and analyzed in this paper. The results show that to fill the tubing with foam-glass beads or high pressure argon may lead to a good performance.

关键词: vacuum insulated tubing     cyclic steam stimulation     insulation material     thermal conductivity     foam-glass     hydrogen permeation    

Performance of insulated FRP-strengthened concrete flexural members under fire conditions

Pratik P. BHATT, Venkatesh K. R. KODUR, Anuj M. SHAKYA, Tarek ALKHRDAJI

《结构与土木工程前沿(英文)》 2021年 第15卷 第1期   页码 177-193 doi: 10.1007/s11709-021-0714-z

摘要: This paper presents the results of fire resistance tests on carbon fiber-reinforced polymer (CFRP) strengthened concrete flexural members, i.e., T-beams and slabs. The strengthened members were protected with fire insulation and tested under the combined effects of thermal and structural loading. The variables considered in the tests include the applied load level, extent of strengthening, and thickness of the fire insulation applied to the beams and slabs. Furthermore, a previously developed numerical model was validated against the data generated from the fire tests; subsequently, it was utilized to undertake a case study. Results from fire tests and numerical studies indicate that owing to the protection provided by the fire insulation, the insulated CFRP-strengthened beams and slabs can withstand four and three hours of standard fire exposure, respectively, under service load conditions. The insulation layer impedes the temperature rise in the member; therefore, the CFRP–concrete composite action remains active for a longer duration and the steel reinforcement temperature remains below 400°C, which in turn enhances the capacity of the beams and slabs.

关键词: concrete beams     concrete slabs     carbon fiber-reinforced polymers     fire resistance     FRP strengthening     repair     retrofitting    

8英寸绝缘栅双极型晶体管 (IGBT) 关键技术研究 Article

刘国友,丁荣军,罗海辉

《工程(英文)》 2015年 第1卷 第3期   页码 361-366 doi: 10.15302/J-ENG-2015043

摘要:

基于8英寸绝缘栅双极型晶体管 (IGBT) 生产线的建设,重点解决了8英寸IGBT先进工艺技术、第四代高压双扩散金属氧化物半导体 (DMOS+) IGBT技术和第五代沟槽栅IGBT技术等关键技术问题,实现了高压IGBT芯片制造从6英寸到8英寸的技术突破,自主开发的1600 A/1.7 kV与1500 A/3.3 kV IGBT模块已经被成功制造并通过考核,现已应用于轨道交通牵引系统。

关键词: 绝缘栅双极型晶体管 (IGBT)     高功率密度     沟槽栅     8英寸     轨道交通    

A novel algorithm for frequency dependent modeling of ferrite ring and its optimum design to study VFTO behaviors within GIS

Mehrdad MAJIDI, Hamid JAVADI, Moein MANBACHI

《能源前沿(英文)》 2014年 第8卷 第1期   页码 90-100 doi: 10.1007/s11708-013-0286-2

摘要: One of the fundamental issues in gas insulated substations (GIS) which has destructive effects on GIS equipment is the very fast transient over-voltages (VFTOs). This paper models a 400/230 kV substation in order to study the effects of VFTO extensively implemented on EMTP-RV. In addition, the application of ferrite rings for suppressing VFTOs is assessed thoroughly. The main advantage of this paper is its new proposed algorithm according to the ferrite ring frequency dependent modeling that is validated with experimental results. This paper examines the effects of three compositions of the ferrite ring on VFTO suppression. Moreover, it estimates the dimension of the ferrite ring based on the SF6 gas insulation withstand and the maximum effect of ferrite rings on VFTO suppression constraint with the COMSOL multiphysics software. Furthermore, it gains VFTO attenuated percentages due to the installation of the ferrite ring in different GIS nodes. Finally, it analyzes the offered VFTO amendment technique in various GIS switching scenarios.

关键词: comsol multiphysics     EMTP-RV     ferrite ring     gas insulated substations (GIS)     transient over-voltage     insulation coordination    

Experimental study on fire protection methods of reinforced concrete beams strengthened with carbon fiber reinforced polymer

HU Kexu, HE Guisheng, LU Fan

《结构与土木工程前沿(英文)》 2007年 第1卷 第4期   页码 399-404 doi: 10.1007/s11709-007-0054-7

摘要: In this paper, two reinforced concrete (RC) beams strengthened with carbon fiber reinforced polymer (CFRP) and attached with thick-painted fire resistant coating were tested for fire resistance following the standard fire testing procedures. The experimental results show that the specimen pasted with the insulated layer of 50 mm in thickness could resist fire for 2.5 h. It is also demonstrated that the steel wire mesh embedded in the insulated layer can effectively prevent it from cracking and eroding under firing.

关键词: polymer     insulated     resistant     CFRP     resistance    

标题 作者 时间 类型 操作

Novel methods by using non-vacuum insulated tubing to extend the lifetime of the tubing

Chenglong ZHOU,Guojin ZHU,Yongxiang XU,Jifei YU,Xiaoliang ZHANG,Hongzhi SHENG

期刊论文

Performance of insulated FRP-strengthened concrete flexural members under fire conditions

Pratik P. BHATT, Venkatesh K. R. KODUR, Anuj M. SHAKYA, Tarek ALKHRDAJI

期刊论文

8英寸绝缘栅双极型晶体管 (IGBT) 关键技术研究

刘国友,丁荣军,罗海辉

期刊论文

A novel algorithm for frequency dependent modeling of ferrite ring and its optimum design to study VFTO behaviors within GIS

Mehrdad MAJIDI, Hamid JAVADI, Moein MANBACHI

期刊论文

Experimental study on fire protection methods of reinforced concrete beams strengthened with carbon fiber reinforced polymer

HU Kexu, HE Guisheng, LU Fan

期刊论文