Resource Type

Journal Article 9

Year

2018 1

2015 1

2014 4

2009 1

2007 1

2006 1

Keywords

power quality 2

shunt active filter 2

total harmonic distortion (THD) 2

Bus communication 1

DC/DC converter (Boost) 1

DSTATCOM 1

Fault-tolerant topology 1

Forty-three 1

Shunt active power filter 1

Split-phase control 1

active power filter (APF) 1

bleeding 1

clamped plate 1

clinical efficacy 1

current harmonics mitigation 1

diameter 1

digital signal processor (DSP) 1

distorted voltage conditions 1

evacuation arithmetic 1

fuzzy logic control 1

open ︾

Search scope:

排序: Display mode:

Vibration control efficiency of piezoelectric shunt damping system

Dan WU, Zhichun YANG, Hao SUN,

Frontiers of Mechanical Engineering 2009, Volume 4, Issue 4,   Pages 441-446 doi: 10.1007/s11465-009-0055-4

Abstract: The piezoelectric shunt damping technique based on the direct piezoelectric effect has been known asWhen applying the piezoelectric shunt damping technique to passively control structural vibration, theIn this paper, the concept of vibration control efficiency of a piezoelectric shunt damping system isplates, respectively, and vibration control experiments are conducted for these plates using the R-L shuntIt comes to a conclusion that the vibration control efficiency of the piezoelectric shunt damping system

Keywords: piezoelectric shunt     vibration control efficiency     clamped plate     generalized electromechanical coupling    

A simple digital control algorithm for three phase shunt active filter: simulation and experimentation

Subbaraman SRINATH, Chandan KUMAR, M. P. SELVAN

Frontiers in Energy 2014, Volume 8, Issue 1,   Pages 119-128 doi: 10.1007/s11708-013-0288-0

Abstract: control algorithm using digital signal processor (DSP) has been proposed and realized for a three phase shunt

Keywords: shunt active filter (SAF)     power quality     voltage source inverter (VSI)     digital signal processor (DSP)    

Partial portacaval shunt with H-grafts to treat portal hypertension

XU Geliang, HU Hejie, LI Jiansheng, YANG Shugao, CHAI Zhongpei, XU Rongnan

Frontiers of Medicine 2007, Volume 1, Issue 3,   Pages 279-281 doi: 10.1007/s11684-007-0053-z

Abstract: partial portacaval shunts [small-diameter expanded polytetrafluoroethylene (ePTFE) H-graft portacaval shuntForty-three patients with portal hypertension were treated by small-diameter H-graft of ePTFE portacaval shuntThe portal blood flow was reduced by one-third of that before shunt.The morbidity of encephalopathy was lower than those with total shunt.The partial portacaval shunt is effective in preventing recurrent variceal bleeding.

Keywords: diameter     clinical efficacy     bleeding     pericardial devascularization     Forty-three    

Power quality improvement using fuzzy logic controller for five-level shunt active power filter under

Amar BENAISSA,Boualaga RABHI,Ammar MOUSSI

Frontiers in Energy 2014, Volume 8, Issue 2,   Pages 212-220 doi: 10.1007/s11708-013-0284-4

Abstract: In this paper, a five-level inverter is used as a shunt active power filter (APF), taking advantagesThe obtained results show that the proposed shunt APF controller has produced a sinusoidal supply current

Keywords: active power filter (APF)     harmonics isolator     distorted voltage conditions     self-tuning filters (STF)     fuzzy logic control    

Performance investigation of artificial intelligence based controller for three phase four leg shunt

J. JAYACHANDRAN,R. MURALI SACHITHANANDAM

Frontiers in Energy 2015, Volume 9, Issue 4,   Pages 446-460 doi: 10.1007/s11708-015-0378-2

Abstract: In this paper, the choice of power quality compensator is a DSTATCOM which constitutes a three phase four leg voltage source converter (VSC) with a DC capacitor. The control strategy proposed for the DSTATCOM is a neural network based one cycle control (OCC). This control strategy involves neural network block, digital circuits and linear elements, which eliminates the sensors required for sensing the load current and coupling inductor current in addition to the multiplier employed in the conventional method. The calculation of harmonic and reactive currents for the reference current generation is also eliminated, thus minimizing the complexity in the control strategy. The control strategy mitigates harmonic/reactive currents, ensures balanced and sinusoidal source current from the supply mains that are nearly in phase with the supply voltage, compensates neutral current, and maintains voltage across the capacitor under unbalanced source and load conditions. The performance of the DSTATCOM with the proposed artificial neural network (ANN) controllers is validated and investigated through simulations using Matlab software. The simulation results prove the efficacy of the proposed neural network based control strategy under varying source and load conditions.

Keywords: neural network     DSTATCOM     neutral current mitigation     total harmonic distortion (THD)     three phase four wire distribution system     unbalanced and/or distorted source    

An Algorithm of Evacuation Time Which Simulates the Evacuation Course

Zhu Jiaying,Zhang Heping

Strategic Study of CAE 2006, Volume 8, Issue 8,   Pages 73-76

Abstract: were abstracted as units of the net, and the evacuation course was simplified as series-wound net, shunt-wound

Keywords: evacuation arithmetic     room unit     series-wound model     shunt-wound model    

A multi-modular shunt active power filter system and its novel fault-tolerant strategy based on split-phase None

Qun-wei XU, Jin-xiang ZHAN, Long XIAO, Guo-zhu CHEN

Frontiers of Information Technology & Electronic Engineering 2018, Volume 19, Issue 9,   Pages 1166-1179 doi: 10.1631/FITEE.1601296

Abstract:

We first present a new multi-modular shunt active power filter system suitable for large-capacity

Keywords: Shunt active power filter     Fault-tolerant topology     Split-phase control     Bus communication    

Rapid transaction to load variations of active filter supplied by PV system

M. BENADJA,S. SAAD,A. BELHAMRA

Frontiers in Energy 2014, Volume 8, Issue 3,   Pages 335-344 doi: 10.1007/s11708-014-0325-7

Abstract: and control of a photovoltaic (PV) system connected to the main supply through a Boost converter and shuntTo demonstrate the effectiveness of the shunt active filter to load changes, the method of instantaneous

Keywords: solar panels     maximum power point tracking (MPPT)     DC/DC converter (Boost)     shunt active filter     instantaneous    

Unified power quality conditioner based on a three-level NPC inverter using fuzzy control techniques for all voltage disturbances compensation

Salim CHENNAI,M-T BENCHOUIA

Frontiers in Energy 2014, Volume 8, Issue 2,   Pages 221-239 doi: 10.1007/s11708-014-0317-7

Abstract: It is designed by the integration of series and shunt active filters (AFs) sharing a common DC bus capacitorThe synchronous reference frame (SRF) theory is used to get the reference signals for shunt active powerThe shunt and series APF reference signals derived from the control algorithm and sensed signals are

Keywords: conditioner (UPQC)     current harmonics mitigation     fuzzy logic controller     voltage disturbance compensation     shunt    

Title Author Date Type Operation

Vibration control efficiency of piezoelectric shunt damping system

Dan WU, Zhichun YANG, Hao SUN,

Journal Article

A simple digital control algorithm for three phase shunt active filter: simulation and experimentation

Subbaraman SRINATH, Chandan KUMAR, M. P. SELVAN

Journal Article

Partial portacaval shunt with H-grafts to treat portal hypertension

XU Geliang, HU Hejie, LI Jiansheng, YANG Shugao, CHAI Zhongpei, XU Rongnan

Journal Article

Power quality improvement using fuzzy logic controller for five-level shunt active power filter under

Amar BENAISSA,Boualaga RABHI,Ammar MOUSSI

Journal Article

Performance investigation of artificial intelligence based controller for three phase four leg shunt

J. JAYACHANDRAN,R. MURALI SACHITHANANDAM

Journal Article

An Algorithm of Evacuation Time Which Simulates the Evacuation Course

Zhu Jiaying,Zhang Heping

Journal Article

A multi-modular shunt active power filter system and its novel fault-tolerant strategy based on split-phase

Qun-wei XU, Jin-xiang ZHAN, Long XIAO, Guo-zhu CHEN

Journal Article

Rapid transaction to load variations of active filter supplied by PV system

M. BENADJA,S. SAAD,A. BELHAMRA

Journal Article

Unified power quality conditioner based on a three-level NPC inverter using fuzzy control techniques for all voltage disturbances compensation

Salim CHENNAI,M-T BENCHOUIA

Journal Article