Using WIMS & CITATION program, the neutronic parameters calculating model of in-hospital neutron irradiator mark 1(IHNI-1) reactor is presented in this paper.The power distribution, reactivity worth of control rod and top beryllium, temperature coefficient and burnup are calculated. It proves that the results are consistent with the literature values and the method is appropriate to physical calculation of IHIN-1 reactor.