Journal Home Online First Current Issue Archive For Authors Journal Information 中文版

Strategic Study of CAE >> 2012, Volume 14, Issue 8

MCDB Monte Carlo dosimetry code system and its applications

Institute of Applied Physics and Computational Mathematics, Beijing 100094, China

Received: 2012-05-30 Available online: 2012-07-26 09:05:09.000

Next Previous

Abstract

MCDB is developed for boron neutron capture therapy (BNCT). This system consists of a medical pre-processor, a dose computation and a post-processor. MCDB automatically produces the input file from CT and MRI image data. In Monte Carlo dose calculation, several accelerated measures, such as the fast track technique, mesh tally matrix and material matrix, are developed. In this paper, we proposed a real model simulated by MCNP and MCDB, respectively. The almost same results as MCNP are achieved. MCDB is faster in computational speed than MCNP.

Figures

图1

图2

图3

图4

图5

图6

References

[ 1 ] Rore A, Wambersie G, Whitmore R. Current status of neutron cap-ture therapy[R].2001, IAEA.

[ 2 ] Gonzalez S, Santa CruzJ, Kiger IⅢ W, et al. NCTplan, the New PC version of MacNCTplan: improvements and verification of a BNCT treatment planning system[C]//Proceedings of the 10h In-ternational Congress on Neutron Capture Therapy for Cancer.2002, Essen, Germany.

[ 3 ] Seppali, Kankaanranta L, Seren T, et al. BNCT_RTPE and SERA dose planning programs: phantom and patient studies[C]//Program and abstracts of 9h Intermational Symposium on Neutron Capture Therapy for Cancer. ISNCT: Osaka,2000,175-176.

[ 4 ] Kumada H, Yamamoto K, Matsumura A, et al. Verification of the computational dosimetry system in JAERI(JCDS) for boron neu-tron capture therapy[J]. Phys Med Biol,2004,49:3353-3365. link1

[ 5 ] Li Deng, Gang Li, Tao Ye, et al. MCDB Monte Carlo code with fast track technique and mesh tally matrix for BNCT[J].J Nucl Sci Tech,2007,44:1518-1525. link1

[ 6 ] ICRU-63. Nuclear data for neutron and proton radiotherapy and for radiation protection, ICRU report No.63[R]. International Commission on Radiation Units and Measurements,2000.Bethes-da,MD.

[ 7 ] Briesmeister J F.MCNP-a general Monte Carlo code for n-particle transport code[R].LA-12625-M,1997.

[ 8 ] Goorley JT,Kiger IIl W s,Zamenhof R G.Reference dosimetry calculations for neutron capture therapy with comparison of analyti-cal and voxel models[J].Med Phys,2002,29(2):145-156. link1

[ 9 ] Gang Li,Li Deng.Optimized voxel model construction and simula-tion research in BNCT[J].HEP&NP,2006,30:171-177. link1

[10] 李刚.BNCT的蒙特卡罗模拟方法研究及软件研制[D].北京:中国工程物理研究院北京研究生部,2005. link1

Related Research