The burnup calculation for in-hospital neutron irradiator mark 1 reactor based on coupled code of WIMS and MCNP

1. Northwest Institute of Nuclear Technology, Xi'an 710024, China;

2. China Zhongyuan Engineering Corporation, China National Nuclear Corporation, Beijing 100191, China

Received: 2012-04-06 Available online: 2012-07-26 09:05:08.000

Next Previous

Abstract

The paper set up the coupled calculation methods of criticality and burnup based on WIMS code and MCNP code, and validated the method. Through the calculation results of cells and the comparison of burnup experiments of Xi’an pulsed reactor, the validity and rationality of the coupled code were proved. The article utilized the coupled code to compute and analyze the burnup of in hospital neutron irradiator mark 1(IHNI-1) reactor at last.