Study on the transient behaviours of in-hospital neutron irradiator mark 1 reactor in accident condition

1. Northwest Institute of Nuclear Technology, Xi'an 710024, China;

2. China Zhongyuan Engineering Corporation, China National Nuclear Corporation, Beijing 100191, China

Received: 2012-04-06 Available online: 2012-07-26 09:05:08.000

Next Previous

Abstract

RELAP5/SCDAP/MOD3.4 is used to simulate and analyze the transient proceeding of in-hospital neutron irradiator mark 1(IHNI-1) reactor in accident condition.Large reactivity insertion accident and loss of coolent of pool accident are calculated and analyzed.The results show that IHNI-1 reactor is characterized with inherent safety. The negative coolant temperature feedback limits the nuclear power to an stable level and the reactor is safe under the accident.

Figures

图1

图2

图3

图4

图5

图6

图7

图8

References

[ 1 ] 苏云,许以全,曹学武,等.SCDAP/RELAP5程序结构及严重事故有关的模型概述[J].核动力工程,2003,24(6):51-55. link1

[ 2 ] 江新标,张文首,高集金,等.低浓化医院中子照射器(IHNI-1)堆芯的物理方案设计[J].中国工程科学,2009,11(11):17-21. link1

[ 3 ] 张鸿雁,张志政,王元.流体力学[M].北京:科学出版社,2004.

Related Research